Page 10 of 11
WC13PS SERIES RESTROOM CONTROL
INSTALLATION INSTRUCTIONS
120 VAC
Door Position Switch
Transformer
CX-TRX-5024
24 VAC, 50 VA
Door Operator
N.C.
PUSH
TO OPEN
Re
m
ot
e
12/24V Power
N.O. Relay Output
Outside Wall Switch
CM-45/455SE1 (or similar)
AC
AC
Outside
Push To Open
Inside
Push To Open
Push To
Lock
DPS NC
DPS COMM
+
WET
- INPUT
+ Lock
+ Strike
-
St rike
*
Door
Operator
*
LED
Control
*
+ VDC
-
VDC
Aura
Dip Switch
Settings
1
2
3
4
CM-AF540SO
CM-AF141SO
GRY
BLK
N/O
N/C
BLK
GRY
CX-WEC10-K2
Emergency Call System Wiring
Connect directly to DPS if no Emergency Call System is installed
CX-WC13AXFM-PS Wiring Diagram with CX-WEC10-K2 Integration
Model: 60-40E033
CM-2520/4855SE1 (or similar)
PUSH
TO
OPEN
PUSH
TO
LOCK
Inside
‘Push To Open (always unlocks & opens door)
& Push to Lock’ combination Switch
12
/24
Power
Remote
N.
O.
Relay Output
Pus
h To
Open
IMPORTANT:
Ensure wiring polarity is consistent from Relay 3
to each Aura Remote Input terminals
FILENAME:
DRAWING No:
SCALE: NONE
DRAWN BY:
REV:
DATE:
CAMDEN DOOR CONTROLS
5502 Timberlea Blvd
Mississauga, Ontario
L4W 2T7
JML
Jan 20, 2020
1
CX-WC13AXFM/SM-PS & CX-WEC10K2 Wiring Diagram
Electric Strike
CX-ED2079
Notes
1. CX-33 can be set to Mode 7 (Normally Unlocked)
or Mode 8 (Normally Locked).
2. Mode 7 = Set Set Strike to Fail Safe.
3. Mode 8 = Set Strike to Fail Secure.
Wire MOV
directly to
strike or
magnet
MOV
1
REM/LOC
RELAY
SPEAKER
2
3
Enable
ON
1
RED
GREEN
BLUE
RED
GREEN
BLUE
2
3
Active Color
ON
1
2
3
Idle Color
ON
= Switch Position