CX-DE1200 Delayed Egress Electro Magnetic Lock

INSTALLATION INSTRUCTIONS

Step 8 

After the lock unit has been mounted to the door and frame as per the provided template, route the wires through the access hole 

and out to the controller board. Re-mount the lock front cover onto the lock. Make sure the proxy sensor is aligned with the hole on 

the cover. The sensor height is factory default which slightly projected out from the surface cover.

CAUTION: 

Do not attempt to adjust the proxy sensor height, as this will result in damage to the sensor and void the warranty.

 

Step 9 

Make all wiring connections to the lock controller board. Special precaution on the polarity of the input power terminals. This lock 

has auto sensing voltage feature which automatically configures itself for 12 VDC or 24 VDC operation. Correct power supply voltage 

must be used for proper lock operation.

NOTE:

 The length of wiring to all field-wiring terminals shall not exceed 98.5 ft (30 m)

CAUTION: 

Input terminals for R-Exit, Reset & Ex-Trig must only be connected to a normally open momentary dry contact switch. 

Connection to a voltage or "wet" output may damage the lock and void the warranty.

Step 10 

Slowly swing the door closed and visually check the position of the proxy trigger as it approaches the proxy sensor on the lock. The 

proxy trigger & sensor should align between one another either horizontally or vertically, if the installation was done perfectly using 

the provided mounting template. The LED at the back of the proxy sensor will light on when the proxy trigger is detected.

IMPORTANT NOTICE: 

Standard operation of the lock depends on the proxy sensor being able to detect the proxy trigger when the 

door is swing closed. A minor adjustment can be made to the proxy sensor height for fine tuning.

Step 11 

Fine Tuning Proxy Sensor Height:

 

- Turning proxy sensor holder clockwise (CW) will increase the height of the proxy sensor from the front cover surface; 

  hence decreasing the gap between the sensor and proxy trigger.
- Turning proxy sensor holder counterclockwise (CCW) will decrease the height of the proxy sensor from the front cover surface; 

  hence increasing the gap between the sensor and proxy trigger.

Step 12 

Fine Tuning Door Movement Detection Sensitivity:
The proxy trigger is spring loaded and can be screwed in or out from the proxy trigger ABS housing using the provided Allen key M5. 

Hence, increase or decrease the gap between the sensor and proxy trigger.

IMPORTANT NOTICE: 

Standard installation of the proxy sensor and proxy trigger does not have to touch each other physically to 

operate correctly.

PROXY SENSOR

PROXY SENSOR HOLDER

DOOR

CW

CCW

PROXY TRIGGER

Release Time:

 

The Release time can be selectable either 15 or 30 seconds. The Nuisance time delay is included in the door Release cycle and the 

total time to unlock the door remain the same as per setting once sensor is triggered.

Nuisance Time:

 

The Nuisance time feature is a warning time delay that commences when pressure is applied to outward swinging doors. Releasing 

the door before the end of the nuisance time, will turn off the warning alarm buzzer and reset nuisance time to origin. Nuisance 

time is field selectable for 1, 2 or 3 seconds. Triggering the proxy sensor beyond the nuisance time will start the irreversible Release 

cycle time. The Nuisance time is included in the lock Release time cycle.

Содержание CX-DE1200

Страница 1: ...Output 12 24 VDC 1A Lock Status Relay Rating Max 30 VDC 2A 1 pF Alarm Output Rating Max 30 VDC 2A 1 pF DPS Rating Max 30 VDC 0 1A 1 pF BondSensorRatingMax 30 VDC 2A 1 pF ATS Rating Max 30 VAC 42 4 VDC 5A 1 pF Operating Temperature 0 55 C 32 131 F Operating Humidity 0 95 non condensing Dimensions Lock 11 H x 3 W x 3 D 280mm x 76mm x 74 5mm Dimensions Armature Plate 11 H x 2 5 8 W x 1 D 280mm x 68mm...

Страница 2: ... Prevention door will re lock as soon as it closes Anti Pass Back Auto re lock If door doesn t open after the count down the door will automatically re lock 5 INSTALLATION CONCEPT AND ACCESSORIES Seven configuration versions are available to be compliant to regional jurisdictions Models Delay Release Time Seconds Nuisance Delay Seconds Reset After Alarm Lock Status on Power Up Fixed Selectable Fix...

Страница 3: ...led Factory default setting Jumper J10 Fire Panel Input Uninstalled Only if a dry contact NC from a fire alarm panel or smoke detector system is connected to the Fire P terminals Door unlocked alarm sounding until reset Display Mode Jumper Settings Push Bar Optional CM 120i Keypad optional AC Main Fire Panel 2 Core Cable 3 Core Cable Power Supply Push Bar Ex Trig Keypad Key Switch Built In Key Swi...

Страница 4: ... hole position IG DE1200 280 Ver 1019 Out Swing Door Only Door Frame Door Frame Door Frame Door Frame Armature Plate Armature Housing Temporary mount with self tapping screw EZ Interlocking Mounting Plate Screw 2 Screw 1 2 Drill mark the screw hole according to the template holes Door Frame Mounting Template Door 1 Door Door Door Spring Armature Screw Proxy Trigger Door Step 1 Close the door posit...

Страница 5: ...g screws Step 6 Align the lock unit with the mounting plate Fix the lock unit to the mounting plate with the allen key given through fixing the screw Carefully screw into the mounting plate to avoid stripping the threads Check and confirm the alignment and mating surface between the armature plate and lock unit NOTICE Loosen screw 1 or 2 to re align the mounting plate and position the lock unit ma...

Страница 6: ...OTICE Standard operation of the lock depends on the proxy sensor being able to detect the proxy trigger when the door is swing closed A minor adjustment can be made to the proxy sensor height for fine tuning Step 11 Fine Tuning Proxy Sensor Height Turning proxy sensor holder clockwise CW will increase the height of the proxy sensor from the front cover surface hence decreasing the gap between the ...

Страница 7: ...counted along with verbal exit guidance When the LED bar display reaches zero the lock will release The verbal voice guidance changes to a continuous verbal instruction announcing Door Unlocked In TONE ONLY mode the countdown will be accompanied with a beeping tone only and a continuous tone is heard once the Release time cycle ends Languages The voice message can be in 3 languages which are field...

Страница 8: ... Internal OFF Unlocked Not Used Stand by OFF 5 OFF Fixed Manual 15 1 ON 15 Sec OFF OFF External ON Unlocked Alarm ON 1 ON NFPA OSHPD Compliant Power Up unlocked and manual reset is fixed 20 Sec ON OFF 30 Sec OFF ON Not Used Switch 8 B1 15 Not Used 0 OFF 1 Sec ON ON Internal OFF Unlocked OFF Stand by OFF Manual OFF 15 3 ON 15 Sec OFF OFF External ON Locked ON Alarm ON Auto ON BOCA Compliant Automat...

Страница 9: ...is NOT on the armature Anti Tamper Switch This contact will change state when the cover is removed External Trigger Wire from of Tandem CX DE1220 lock Power Supply for accessories Fire Alarm Input Supervised Normally Closed J10 jumper must be removed Wire connection to Tandum Lock CX DE1220 Lock Status The bond sensor will monitor the surface of the armature This contact will change state when the...

Отзывы: