CX-DE1200 Delayed Egress Electro Magnetic Lock

INSTALLATION INSTRUCTIONS

6. ARMATURE MOUNTING INSTRUCTIONS

Out Swing

DE1200-TEMPLATE with FB-DE1200-280

FOLD 90° ON THIS DOTTED LINE

Note: Dimensions might change if photocopied.

Place Against

Door Frame

FB-DE1200 Template

Drill 1/2"

Dia. for Cable

Access Hole

Install the mounting plate at 2

slots position first, then make

proper adjustment before

marking remaining screws

hole position.

Armature Housing-DE1200 Template

Place Against Door

Install the Armature Housing

with 2 screws position

first, then make proper

adjustment before marking

remaining screws hole position.

IG-DE1200-280 Ver.1019

Out-Swing

Door Only

Door Frame

Door Frame

Door Frame

Door Frame

Armature Plate

Armature Housing

Temporary mount with self tapping screw

EZ Interlocking 

Mounting Plate

Screw #2

Screw #1

2.

 Drill mark the 

    screw hole

    according to the 

    template holes

    (Door & Frame) 

Mounting Template

Door

1”

Door

Door

Door

Spring

Armature Screw

Proxy 

Trigger

Door

Step 1: 

Close the door, position the EM lock mounting location as close to the upper corner of the door with a minimum gap 1".

Step 2: 

Place the template against the door and frame and drill holes according to template indications.

Step 3: 

Place the mounting plate against the door frame and screw in according to the template holes position.

Step 4: 

Place the armature housing against the door and screw in according to the template holes position

Содержание CX-DE1200

Страница 1: ...Output 12 24 VDC 1A Lock Status Relay Rating Max 30 VDC 2A 1 pF Alarm Output Rating Max 30 VDC 2A 1 pF DPS Rating Max 30 VDC 0 1A 1 pF BondSensorRatingMax 30 VDC 2A 1 pF ATS Rating Max 30 VAC 42 4 VDC 5A 1 pF Operating Temperature 0 55 C 32 131 F Operating Humidity 0 95 non condensing Dimensions Lock 11 H x 3 W x 3 D 280mm x 76mm x 74 5mm Dimensions Armature Plate 11 H x 2 5 8 W x 1 D 280mm x 68mm...

Страница 2: ... Prevention door will re lock as soon as it closes Anti Pass Back Auto re lock If door doesn t open after the count down the door will automatically re lock 5 INSTALLATION CONCEPT AND ACCESSORIES Seven configuration versions are available to be compliant to regional jurisdictions Models Delay Release Time Seconds Nuisance Delay Seconds Reset After Alarm Lock Status on Power Up Fixed Selectable Fix...

Страница 3: ...led Factory default setting Jumper J10 Fire Panel Input Uninstalled Only if a dry contact NC from a fire alarm panel or smoke detector system is connected to the Fire P terminals Door unlocked alarm sounding until reset Display Mode Jumper Settings Push Bar Optional CM 120i Keypad optional AC Main Fire Panel 2 Core Cable 3 Core Cable Power Supply Push Bar Ex Trig Keypad Key Switch Built In Key Swi...

Страница 4: ... hole position IG DE1200 280 Ver 1019 Out Swing Door Only Door Frame Door Frame Door Frame Door Frame Armature Plate Armature Housing Temporary mount with self tapping screw EZ Interlocking Mounting Plate Screw 2 Screw 1 2 Drill mark the screw hole according to the template holes Door Frame Mounting Template Door 1 Door Door Door Spring Armature Screw Proxy Trigger Door Step 1 Close the door posit...

Страница 5: ...g screws Step 6 Align the lock unit with the mounting plate Fix the lock unit to the mounting plate with the allen key given through fixing the screw Carefully screw into the mounting plate to avoid stripping the threads Check and confirm the alignment and mating surface between the armature plate and lock unit NOTICE Loosen screw 1 or 2 to re align the mounting plate and position the lock unit ma...

Страница 6: ...OTICE Standard operation of the lock depends on the proxy sensor being able to detect the proxy trigger when the door is swing closed A minor adjustment can be made to the proxy sensor height for fine tuning Step 11 Fine Tuning Proxy Sensor Height Turning proxy sensor holder clockwise CW will increase the height of the proxy sensor from the front cover surface hence decreasing the gap between the ...

Страница 7: ...counted along with verbal exit guidance When the LED bar display reaches zero the lock will release The verbal voice guidance changes to a continuous verbal instruction announcing Door Unlocked In TONE ONLY mode the countdown will be accompanied with a beeping tone only and a continuous tone is heard once the Release time cycle ends Languages The voice message can be in 3 languages which are field...

Страница 8: ... Internal OFF Unlocked Not Used Stand by OFF 5 OFF Fixed Manual 15 1 ON 15 Sec OFF OFF External ON Unlocked Alarm ON 1 ON NFPA OSHPD Compliant Power Up unlocked and manual reset is fixed 20 Sec ON OFF 30 Sec OFF ON Not Used Switch 8 B1 15 Not Used 0 OFF 1 Sec ON ON Internal OFF Unlocked OFF Stand by OFF Manual OFF 15 3 ON 15 Sec OFF OFF External ON Locked ON Alarm ON Auto ON BOCA Compliant Automat...

Страница 9: ...is NOT on the armature Anti Tamper Switch This contact will change state when the cover is removed External Trigger Wire from of Tandem CX DE1220 lock Power Supply for accessories Fire Alarm Input Supervised Normally Closed J10 jumper must be removed Wire connection to Tandum Lock CX DE1220 Lock Status The bond sensor will monitor the surface of the armature This contact will change state when the...

Отзывы: