CX-DE1200 Delayed Egress Electro Magnetic Lock

INSTALLATION INSTRUCTIONS

CX-DESPK15

15 Watt

Speaker

Plug in

Power Supply 

12 VDC

PWR

+

    

_

PWR

+

    

_

GRN Rly

 NO   C     NC

RED Rly

 NO   C     NC

Ex-Trig

 NO     C

Reset

 NO     C

R-Exit

 NO      C

Bypass

 NO      C

+

_

_

_

_

+

+

GND

INL

+

CX-TRP-612DC

CM-1100/7212

Remote

Reset Station

Ex. Spkr

+

    

_

PWR

+

    

_

PWR

+

    

_

Ex. Spkr

+

    

_

PWR

+

    

_

PWR

+

    

_

Lock

+

    

_

Fire P

 C     NC

Lock

+

    

_

Fire P

 C     NC

CM-DE502SO

Remote

Audible-Visual

Station

PWR

+

    

_

PWR

+

    

_

GRN Rly

 NO   C     NC

RED Rly

 NO    C      NC

Ex-Trig

 NO     C

Reset

 NO     C

R-Exit

 NO     C

Bypass

 NO     C

Red

Green

B

CM-DESPK

Remote

Audio

Annunciator

+

_

9. ACCESSORIES WIRING

10. COMPLETE WIRING OPTIONS AND FUNCTIONS

File:  CX-DE1200_Manual_R3.indd 

Rev/Date.: 2/11/25/21

Part no.: 40-82B236

Page 6

Terminal Descriptions

Ex. Spkr

 PWR

+ -

NO C NC

+

-

Fire P

C NC

Lock 

GRN Rly

RED Rly

Ex-Trig

Reset R-Exit

Bypass

+

-

NO C NC

NO C NO C NO C

NO C

Wire to 

External 

Speaker

(CX-DESPK 

or

CX-DESPK15)

Power

Supply 

Input

12/24 DC

+/- 10% 

Lock 

Secure 

Output

Alarm

Output

Remote 

Lock Reset

Input

(Wire to

CM-DESPK)

Remote

Request to 

Exit

(Wire from 

remote key 

switch)

Instant Bypass 

Overide Input

 PWR

DPS

NO C NC

Bond-S

NO C NC

ATS

NO C NC

Door 

Position 

Status

 

(This contact 

will change 

state when the 

maglock is 

NOT on the 

armature)

Anti Tamper

Switch

(This contact 

will change 

state when the 

cover is 

removed.)

External 

Trigger  

(Wire from of 

Tandem 

CX-DE1220

lock.)

+

-

Power

Supply for 

accessories

Fire Alarm 

Input

(Supervised, 

Normally 

Closed)

[J10 jumper 

must be 

removed]

Wire 

connection 

to Tandum 

Lock

CX-DE1220

 

Lock Status

 

(The bond 

sensor will 

monitor the 

surface of the 

armature. This 

contact will 

change state 

when the 

electromagnetic 

lock is not 

generating full 

holding 

potential.)

Both contacts will be triggered during the 

countdown before the maglock is 

de-engergized and released.

(The contact 

will change 

state when 

the maglock 

coil is 

energized or 

not 

energized.)

(The contact 

will change 

state when 

the alarm 

has been 

triggered by 

a person 

pressing on 

the door to 

exit.)

WARNING: Improper installation, maintenance, inspection or usage of the product or any related accessories or parts may cause the electromagnetic lock, armature 

plate and associated hardware to disengage and fall, causing serious bodily injury and property damage. Camden will not be liable to the installer, purchaser, end 

user or anyone else for damage or injury to person or property due to improper installation, care, storage, handling, maintenance, inspection, abuse, misuse or act of 

God or nature involving this product or any related accessories or parts. The delayed egress device should be routinely checked for proper operation and compliance 

with fire and building codes. Refer to maintenance document #40-82B292 for additional information.

Содержание CX-DE1200

Страница 1: ...Output 12 24 VDC 1A Lock Status Relay Rating Max 30 VDC 2A 1 pF Alarm Output Rating Max 30 VDC 2A 1 pF DPS Rating Max 30 VDC 0 1A 1 pF BondSensorRatingMax 30 VDC 2A 1 pF ATS Rating Max 30 VAC 42 4 VDC 5A 1 pF Operating Temperature 0 55 C 32 131 F Operating Humidity 0 95 non condensing Dimensions Lock 11 H x 3 W x 3 D 280mm x 76mm x 74 5mm Dimensions Armature Plate 11 H x 2 5 8 W x 1 D 280mm x 68mm...

Страница 2: ... Prevention door will re lock as soon as it closes Anti Pass Back Auto re lock If door doesn t open after the count down the door will automatically re lock 5 INSTALLATION CONCEPT AND ACCESSORIES Seven configuration versions are available to be compliant to regional jurisdictions Models Delay Release Time Seconds Nuisance Delay Seconds Reset After Alarm Lock Status on Power Up Fixed Selectable Fix...

Страница 3: ...led Factory default setting Jumper J10 Fire Panel Input Uninstalled Only if a dry contact NC from a fire alarm panel or smoke detector system is connected to the Fire P terminals Door unlocked alarm sounding until reset Display Mode Jumper Settings Push Bar Optional CM 120i Keypad optional AC Main Fire Panel 2 Core Cable 3 Core Cable Power Supply Push Bar Ex Trig Keypad Key Switch Built In Key Swi...

Страница 4: ... hole position IG DE1200 280 Ver 1019 Out Swing Door Only Door Frame Door Frame Door Frame Door Frame Armature Plate Armature Housing Temporary mount with self tapping screw EZ Interlocking Mounting Plate Screw 2 Screw 1 2 Drill mark the screw hole according to the template holes Door Frame Mounting Template Door 1 Door Door Door Spring Armature Screw Proxy Trigger Door Step 1 Close the door posit...

Страница 5: ...g screws Step 6 Align the lock unit with the mounting plate Fix the lock unit to the mounting plate with the allen key given through fixing the screw Carefully screw into the mounting plate to avoid stripping the threads Check and confirm the alignment and mating surface between the armature plate and lock unit NOTICE Loosen screw 1 or 2 to re align the mounting plate and position the lock unit ma...

Страница 6: ...OTICE Standard operation of the lock depends on the proxy sensor being able to detect the proxy trigger when the door is swing closed A minor adjustment can be made to the proxy sensor height for fine tuning Step 11 Fine Tuning Proxy Sensor Height Turning proxy sensor holder clockwise CW will increase the height of the proxy sensor from the front cover surface hence decreasing the gap between the ...

Страница 7: ...counted along with verbal exit guidance When the LED bar display reaches zero the lock will release The verbal voice guidance changes to a continuous verbal instruction announcing Door Unlocked In TONE ONLY mode the countdown will be accompanied with a beeping tone only and a continuous tone is heard once the Release time cycle ends Languages The voice message can be in 3 languages which are field...

Страница 8: ... Internal OFF Unlocked Not Used Stand by OFF 5 OFF Fixed Manual 15 1 ON 15 Sec OFF OFF External ON Unlocked Alarm ON 1 ON NFPA OSHPD Compliant Power Up unlocked and manual reset is fixed 20 Sec ON OFF 30 Sec OFF ON Not Used Switch 8 B1 15 Not Used 0 OFF 1 Sec ON ON Internal OFF Unlocked OFF Stand by OFF Manual OFF 15 3 ON 15 Sec OFF OFF External ON Locked ON Alarm ON Auto ON BOCA Compliant Automat...

Страница 9: ...is NOT on the armature Anti Tamper Switch This contact will change state when the cover is removed External Trigger Wire from of Tandem CX DE1220 lock Power Supply for accessories Fire Alarm Input Supervised Normally Closed J10 jumper must be removed Wire connection to Tandum Lock CX DE1220 Lock Status The bond sensor will monitor the surface of the armature This contact will change state when the...

Отзывы: