background image

Installation Instructions

6211/6211DS Electric Strike

®

Notes:

Deadbolt will not function with this strike.

Check with factory for retrofit applications.

1.

For lock or device preparation, see their directions.

2.

Prepare frame for strike (see other side).

3.

Wire strike (Figure 1). (Switches on 6211DS only.)

4.

Install insert for auxiliary bolt operation (Figure 2).

5.

Test strike: Apply solenoid power. Fail secure (FSE) lip unlocks.

Fail safe (FS) lip locks. Figure 1 shows status of switches.

6.

Install strike with two #12-24 screws. Make sure clearance
between latch bolt and strike lip is 1/32” (Figure 3). If not,

uninstall strike, adjust (Figure 4), and reinstall.

7.

If latch bolt does not extend far enough to actuate tripper,

install extension (Figure 5). (Tripper on 6211DS only.)

8.

Test door: With strike unlocked, door opens with latch bolt
extended. When door closes, latch bolt rides over strike lip.

931227_00(8) Copyright © 2004 Ingersoll-Rand. All rights reserved.

89/336/EEC

Figure 1

DC input is

nonpolarized

NOTE

!

J1

P1

P1 J1A

P1A

SO-12 or SO-24

12 VDC

or

24 VDC

12 VAC            SO-12     12 VDC
     or
24 VAC            SO-24     24 VDC

{
{

Wiring

for DC

supply

Wiring
for AC

supply

Solenoid

Use crimp

connectors to

splice field wiring

to P1 leads

Figure 2

Fit hook on insert

into notch on

faceplate

Alternate insert

position

Yellow solenoid wires: 12 VDC, 0.57 A

Black solenoid wires: 24 VDC, 0.29 A

(also shown on strike label)

SOLENOID POWER REQUIREMENTS

Use crimp connectors to
splice field wiring to P2
leads; insulate unused leads

Switches hown with tripper

depressed, strike lip closed and locked
(switches and tripper on 6211DS only)

J2

Fail safe (FS)

J2

Fail secure (FSE)

S1

S2

1
2
3
4
5
6

S1

S2

1
2
3
4
5
6

Standard: 5 A, 30 VDC

Gold: 0.25 A, 30 VDC

SWITCH RATINGS

}

P2

Red (C)
Blue
Yellow
White (C)
Gray
Violet

}

S1

(monitors

tripper)

S2

(monitors

strike lip)

J2 P2

Figure 4

To adjust strike, loosen screws

A, B,

 and 

C

 and move backbox

sideways as necessary

A

D

B

C

For more
adjustment,
move screw 

A

to hole 

D

Figure 3

Top view;

faceplate not

shown for clarity

1/32”

Latch bolt

Strike lip

Tripper

Figure 5

Extension

Single Door Mortise or Cylindrical Application

931227-00

Отзывы: