CM-336 BATTERY OPERATED ACTIVE INFRA-RED “HANDS-FREE” SWITCHES

INSTALLATION INSTRUCTIONS

4. APPLICATIONS & SET-UP APPLICATIONS 

See Diagram 3 for the location of the Dip switches.

DIP Switch Settings 
DIP Switch 1

Switch 1 – LED On/LED Off
This switch disables the LED, should this feature be desired. 
Factory setting is OFF. This feature will decrease the battery 
life if set to ON.

Switch 2 – Audio Enable
Set this switch ON to enable an audible beep every time 
the switch is activated. Factory default is OFF. Enabling this 
feature will use additional power and decrease the life of the 
battery.

CM-336

Description

1

LED Enable

Green LED flashes while the output is activated

2

Audio Enable Piezo buzzer sounds when the output is activated

3

Not Used

4

Not Used

Battery Strength Meter
To check the battery strength, place an object in front of 
the Surewave™ switch for approximately 5 seconds. The 
Surewave™ switch will beep up to 5 times indicating the 
battery charge level. 5 beeps being fully charged. 1-3 beeps 
indicates you should change the batteries. 

Adjustments
Once the Dip switches have been set, and the unit is installed 
in the frame or enclosure, apply power to the unit and 
observe operation.
Set both potentiometers to minimum setting initially  
(fully counter-clockwise). 
Adjust the range potentiometer by turning the pot in a 
clockwise manner, and passing your hand in front of the unit. 
Rotate the pot until the desired range is obtained. 
See Diagram 3 for locations.

Diagram 3

1 LED Enable

2 Sounder enable

3 Not used

4 Not used

1

2

3

4

1

2

Activate LED

Error/ 

Alarm LED

Range Adj