background image

9

A Single Room

In the diagram shown below (Figure 10 1), the maximum volume for the room with an QtRC is the same as the 
volume of the emitters in the open area  The power supplied to all of the emitters in the open area is the same 
as the power supplied to the QtRC  The QtRC has the ability to reduce the power supplied to the emitters 
within the closed room  Since a closed room typically requires a lower sound masking level than an open area, 
with the use of a QtRC, a closed room can achieve this lower level by decreasing the maximum level  (Figure 
10 1)

NOTE: 

Each QtRC’s coverage zone may have a maximum of 8 emitters  The maximum number of rooms 

supported on a single run from the CSM controller is determined by ensuring that the total number of emitters 
and QtRCs does not exceed 60 devices 

3V4%

QRGPCTGCECDNGTWP
CPFGOKVVGTU

Figure 10.1

Содержание biamp QtRC

Страница 1: ...Qt Room Control Installation and Operations Guide ...

Страница 2: ...2 ...

Страница 3: ...le of Contents Package Contents 5 Overview 6 Qt Room Control Volume Settings 6 Installing the Qt Room Control 7 Typical Installation Options 7 Two Zone System 7 One Zone System 8 A Single Room 9 Warranty 10 ...

Страница 4: ...4 ...

Страница 5: ...5 Package Contents QtRC Package contains 1 QtRC volume control 1 White Decora style wall plate 1 Manual 1 Set of white tipped screws 2 pieces 1 White knob installed 1 White Decora center plate ...

Страница 6: ...es 2 x 30 emitters then a single run of cable could be used However if a QtRC is also used in each room changing the total to 90 devices 2 x 30 emitters 30 QtRCs then 2 cable runs would be required Qt Room Control Volume Settings The QtRC features a six position switch that adjusts the sound masking volume in approximately 2 5 dB increments The volume will increase as the knob is rotated clockwise...

Страница 7: ...s and diagrams show the various layout options Two Zone System In the diagram below Figure 7 1 the CSM controller has two or more zones The cable run from the first zone black services the open area while the cable run in the second zone red services the 3 closed rooms The first part of the second zone cable run connects to the first QtRC blue box at its built in splitter by the input jack labeled...

Страница 8: ...green is run from the QtRC Room jack to the input port of the first emitter red Then a cable green is run from the output port of the first emitter to the input port of the next emitter red Figure 9 1 The cable that was extended down the hallway reaches a splitter that is used in the same way A cable from splitter 2 goes to the next room connects to QtRC 2 while another cable continues down the ha...

Страница 9: ...o the emitters within the closed room Since a closed room typically requires a lower sound masking level than an open area with the use of a QtRC a closed room can achieve this lower level by decreasing the maximum level Figure 10 1 NOTE Each QtRC s coverage zone may have a maximum of 8 emitters The maximum number of rooms supported on a single run from the CSM controller is determined by ensuring...

Страница 10: ...s will be borne by the purchaser Warranty Limits and Exclusions This warranty ONLY COVERS failures due to defects in materials or workmanship and DOES NOT COVER normal wear and tear or cosmetic damage THIS WARRANTY DOES NOT COVER USE OF THE SYSTEM WITH ANY OTHER EMITTER OR EMITTER MANUFACTURED BY ANY ENTITY ORGANIZATION OR COMPANY OTHER THAN CAMBRIDGE SOUND MANAGEMENT LLC OR USE OF THE SYSTEM FOR ...

Страница 11: ... by these companies All specifications are subject to change Visit cambridgesound com for the latest specification information WARRANTIES ARE LIMITED TO THE PERIOD OF THE WARRANTY This warranty provides specific legal rights and there may be others that vary from state to state or in the country of compliant use Therefore certain additional exclusions may apply 2015 Cambridge Sound Management Inc ...