Chapter 2: System hardware
System Components
Page 2-20
Power supply – PMP/PTP 450i Series
The PMP/PTP 450i Series supports powering from the following powering sources:
Power Supply, 60 W, 56 V with 1000BASE-T or GigE
AC+DC Enhanced Power Injector
Power over Ethernet midspan, 60 W, -48 VDC Input
CMM4 with external 56 V power supply and CMM4 to 450i Series ODU cable (Dongle)
IEEE802.3at power injector
Note
The 900 MHz SM is based off of the 450 Series , please see
Power supply –
PMP/PTP 450 Series
on page
2-26
.
Warning
Always use an appropriately rated and approved AC supply cord-set in
accordance with the regulations of the country of use.
Warning
The PMP 450 Ruggedized High Gain Integrated Subscriber Module (Cambium
part numbers C035045C014A and C036045C014A), while encapsulated in a 450i-
type enclosure, contains 450 circuitry which must be powered via 30
VDC. Powering these SMs with a 56 VDC will damage the device.
Please refer to
Cabling
on Page
2-33
for details on maximum cable lengths between power injector and
PMP/PTP 450i.
PSU part numbers
Table 25
PSU part numbers for PMP/PTP 450i Series
Cambium description
Cambium part number
Power supply, 60 W, 56 V with Gbps support
N000065L001B
AC+DC Enhanced Power Injector
C000065L002C
Line Cord, Fig 8 – US
N000065L003A
Line Cord, Fig 8 – UK
N000065L004A
Line Cord, Fig 8 – EU
N000065L005A
Power over Ethernet midspan, 60 W, -48 VDC Input
N000000L036A
Power supply, 30 W, 56 V – Gbps support
N000000L034A
Содержание PMP 450 AP
Страница 1: ...33F Cambium 450 Platform User Guide System Release 15 2 pass...
Страница 14: ...Contents Page xii 450m overload I Glossary III...
Страница 91: ...Chapter 2 System hardware System Components Page 2 27 Figure 16 Gigabit Enet Capable power supply...
Страница 104: ...Chapter 2 System hardware Cabling Page 2 40...
Страница 139: ...Chapter 3 System planning Typical deployment Page 3 6 Figure 44 GPS receiver tower or mast installation...
Страница 157: ...Chapter 3 System planning Radio Frequency planning Page 3 24 Figure 49 Sector Antenna...
Страница 158: ...Chapter 3 System planning Radio Frequency planning Page 3 25 Figure 50 cnMedusa Antenna...
Страница 189: ...Chapter 3 System planning Remote AP Deployment Page 3 56 Figure 59 Remote AP wired to SM that serves as a relay...