Chapter 2: System hardware
Lightning protection unit (LPU) and grounding kit
Page 2-42
One LPU and grounding kit (
Table 49
) is required for the PSU drop cable connection to the ODU. If the
ODU is to be connected to an auxiliary device, one additional LPU and grounding kit is required for the
Aux drop cable. Order the kits from Cambium Networks (Table 50).
Table 50
LPU and grounding kit part number
Cambium description
Cambium part number
Aux ports LPU and Grounding Kit (One Kit Per End)
C000065L007B
Cable grounding kit
Copper drop cable shields must be bonded to the grounding system in order to prevent lightning-strike
arcing (resulting in fire risk and damage to equipment).
One grounding kit (Figure 27) is required for each grounding point on the cable. Order cable grounding
kits from Cambium Networks (Table 51).
Caution
To provide adequate protection, all grounding cables must be a minimum size of 10 mm
2
csa (8AWG), preferably 16 mm
2
csa (6AWG), or 25 mm
2
csa (4AWG).
Figure 27
Cable grounding kit
Table 51
Cable grounding kit part numbers
Cambium description
Cambium part number
Cable Grounding Kits For 1/4" And 3/8" Cable
01010419001
Содержание PMP 450 AP
Страница 1: ...33F Cambium 450 Platform User Guide System Release 15 2 pass...
Страница 14: ...Contents Page xii 450m overload I Glossary III...
Страница 91: ...Chapter 2 System hardware System Components Page 2 27 Figure 16 Gigabit Enet Capable power supply...
Страница 104: ...Chapter 2 System hardware Cabling Page 2 40...
Страница 139: ...Chapter 3 System planning Typical deployment Page 3 6 Figure 44 GPS receiver tower or mast installation...
Страница 157: ...Chapter 3 System planning Radio Frequency planning Page 3 24 Figure 49 Sector Antenna...
Страница 158: ...Chapter 3 System planning Radio Frequency planning Page 3 25 Figure 50 cnMedusa Antenna...
Страница 189: ...Chapter 3 System planning Remote AP Deployment Page 3 56 Figure 59 Remote AP wired to SM that serves as a relay...