Chapter 7: PTP 820S Detailed Configurations Description
2+0 Dual Polarization Remote Mount
phn-3972 004v000
Page 7-9
Common Installation Procedures
1
Prior to the installation, follow the antenna manufacturer’s instructions to use the
circular
adaptor. (Remove the existing rectangular transition, swap the O-ring, and install the circular
transition instead.)
2 Connect the RFU-C OMT Kit to the antenna and secure it with four screws. Verify the
existence of the O-ring.
3 Mount the two O-Rings supplied with the RFU-C OMT kit on the OMT body. Make sure the
mounting direction is correct, as shown in the section view.