Grounding and lightning protection
This section describes the grounding and lightning protection requirements of a PTP 250
installation.
Electro-magnetic discharge (lightning) damage is not covered under warranty.
The recommendations in this guide, when followed correctly, give the user the
best protection from the harmful effects of EMD. However 100% protection is
neither implied nor possible.
The need for power surge protection
Structures, equipment and people must be protected against power surges (typically
caused by lightning) by conducting the surge current to ground via a separate preferential
solid path. The actual degree of protection required depends on local conditions and
applicable local regulations. Cambium recommends that PTP 250 installation is contracted
to a professional installer.
Standards
Full details of lightning protection methods and requirements can be found in the
international standards IEC 61024-1 and IEC 61312-1, the U.S. National Electric Code
ANSI/NFPA No. 70-1984 or section 54 of the Canadian Electric Code.
International and national standards take precedence over the requirements in this
guide.
Содержание PTP 250
Страница 1: ...Cambium PTP 250 User Guide System Release 250 02 01 ...
Страница 8: ...Safety and regulatory information VI phn 2510_002v000 Mar 2012 ...
Страница 20: ...List of Tables xii phn 2510_002v000 Mar 2012 ...
Страница 58: ...System management Chapter 1 Product description 1 30 phn 2510_002v000 Mar 2012 ...
Страница 104: ...Limit of liability Chapter 3 Legal information 3 12 phn 2510_002v000 Mar 2012 ...
Страница 122: ...Notifications Chapter 4 Reference information 4 18 phn 2510_002v000 Mar 2012 ...
Страница 152: ...Installing the PoE power supply Chapter 5 Installation 5 30 phn 2510_002v000 Mar 2012 ...