PTP 250 User Guide
Installing the drop cable and LPU
phn-2510_002v000 (Mar 2012)
5-25
8
Repeat with a further four layers of PVC tape, always overlapping at half width.
Wrap the layers in alternate directions:
Second layer: top to bottom.
Third layer: bottom to top.
Fourth layer: top to bottom.
Fifth layer: bottom to top.
The edges of each layer should be 25mm (1 inch) above (A) and 25 mm (1 inch)
below (B) the previous layer.
9
Prepare the metal grounding point of the supporting structure to provide a good
electrical contact with the grounding cable clamp. Remove paint, grease or dirt, if
present. Apply anti-oxidant compound liberally between the two metals.
10
Clamp the bottom lug of the grounding cable to the supporting structure using site
approved methods.
Use a two-hole lug secured with fasteners in both holes. This provides better
protection than a single-hole lug.