Site planning
Chapter 2: Planning considerations
2-8
phn-2510_002v000 (Mar 2012)
The lateral force produced by a single PTP 250 ODU (integrated or connectorized model)
at different wind speeds is shown in
Table 7
.
Table 7
Lateral force – metric
Type of ODU
Largest
surface area
(square meters)
Lateral force (Kg) at wind speed
(meters per second)
30
40
50
60
70
Integrated
0.130
12 22 34 49 66
Connectorized
0.093
9 16 24 35 48
Calculation of lateral force (US)
The magnitude of the lateral force can be estimated from:
Force (in pounds) = 0.0042Av
2
Where:
Is:
A
surface area in square feet
v
wind speed in miles per hour
The lateral force produced by a single PTP 250 ODU (integrated or connectorized model)
at different wind speeds is shown in
Table 8
.
Table 8
Lateral force – US
Type of ODU
Largest
surface area
(square feet)
Lateral force (lb) at wind speed
(miles per hour)
80
100
120
140
150
Integrated
1.36
36.6
57.1
82.3
146.2 228.5
Connectorized
1.00
26.9
42
60.5
107.5 168.0
When the connectorized ODU is used with external antennas, the figures from the
antenna manufacturer for lateral force should be included to calculate the total loading
on the mounting structure.
Содержание PTP 250
Страница 1: ...Cambium PTP 250 User Guide System Release 250 02 01 ...
Страница 8: ...Safety and regulatory information VI phn 2510_002v000 Mar 2012 ...
Страница 20: ...List of Tables xii phn 2510_002v000 Mar 2012 ...
Страница 58: ...System management Chapter 1 Product description 1 30 phn 2510_002v000 Mar 2012 ...
Страница 104: ...Limit of liability Chapter 3 Legal information 3 12 phn 2510_002v000 Mar 2012 ...
Страница 122: ...Notifications Chapter 4 Reference information 4 18 phn 2510_002v000 Mar 2012 ...
Страница 152: ...Installing the PoE power supply Chapter 5 Installation 5 30 phn 2510_002v000 Mar 2012 ...