Error Source
Code
Category
Error Message
Possible Cause
Resolution
Front panel
Error
56
Error
Waveform name is not
available.
Waveform name
requested does not exist
Use existing waveform
name from waveform
library
Front panel
Error
57
Error
Waveform file is not
available.
Waveform register
selected is empty
Download valid
waveform data to
selected register
Front panel
Error
58
Error
Waveforms lengths are
different between
inverter controllers.
Waveforms lengths are
not equal between three
phases
Check waveform data for
correct length
Front panel
Error
59
Error
Unit does not exist.
Unit selected cannot be
found
Try recycling power. If
error persists, contact
customer service
Front panel
Error
64
Error
Unexpected reset.
Inverter controllers were
reset
Try recycling power. If
error persists, contact
customer service
Front panel
Error
65
Error
Front panel is in passive
mode.
Passive Mode. Front
panel is most likely an
auxiliary unit
Check parallel
configuration
Front panel
Error
66
Error
Invalid host name.
Host name requested is
invalid
Try recycling power. If
error persists, contact
customer service
Front panel
Error
67
Error
DC voltage set point
cannot change due to
waveform saturation.
Setting conflict.
Waveform data and DC
setting or in conflict
Adjust DC setting or
waveform to resolve
conflict
Front panel
Error
68
Error
AC voltage set point
cannot change due to
waveform saturation.
Setting conflict.
Waveform data and AC
setting or in conflict
Adjust AC setting or
waveform to resolve
conflict
Front panel
Error
69
Error
Maximum user limit is
lower than set point.
Setting conflict. Set point
exceeds upper user limit
Adjust setting or user
limit
Front panel
Error
70
Error
Minimum user limit is
higher than set point.
Setting conflict. Set point
is below lower user limit
Adjust setting or user
limit
Front panel
Error
71
Error
Set point reduced due to
low range.
Setting conflict. Set point
exceeds low voltage
range setting
Select High Range or
lower set point
Front panel
Error
72
Error
Minimum limit is higher
than maximum.
Setting conflict. Max.
User Limit must be higher
than Min. User Limit
Adjust User Limits
Front panel
Error
73
Error
Maximum limit is lower
than minimum.
Setting conflict. Max.
User Limit must be higher
than Min. User Limit
Adjust User Limits
Front panel
Error
74
Error
Waveform description is
not available.
No Waveform Alias name
provided
Assign Alias name to
waveform
Front panel
Error
75
Error
IP address conflict. May
be duplicated.
Duplicate IP detected
Check IP or renew lease
Front panel
Error
76
Error
Invalid filename.
File name invalid
Check file name
Front panel
Error
77
Error
External memory storage
is not available.
Can't find external
memory device selected.
External storage device
selected may have been
removed
Re-insert external
memory device or select
different memory type