AFX SERIES® OPERATION MANUAL
SECTION 8:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS)
• All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 306 of 402
Query Command
SOURce:SYNChronize[:Input]:STATe?
Description
This query only command returns the status of the Phase Lock Loop
(PLL). A “0” response indicates the PLL has not locked on to the sync
input yet. A 1 response indicates the PLL is locked.
Returned Data Format
<b>
Returned Data
0 = PLL is not locked
1 = PLL is locked
Query Example
SOUR:SYNC:STAT?
1
8.10.2.2
SOURce:SYNChronize[:OUTput]
Command Syntax
SOURce:SYNChronize:OUTput
Description
This command enables the SYNC output
Query Format
SOURce:SYNChronize:OUTput?
Returned Data Format
<b>
Returned Data
0 = SYNC output off
1 = SYNCoutput on
Query Example
SOUR:SYNC:OUT?
1