13. Electrical system
45
The power supply cable can be extended with the following requirements
on the wires:
For 12 V system the maximum voltage loss over the extension cable
cannot exceed 0.5 V. For a 5-meter total length of plus and minus
cables, the cross sectional area of the wire needs to be at least 4 mm2
For 24 V system the maximum voltage loss over the extension cable
cannot exceed 1 V. For a 5 to 8-meter total length of plus and minus
cables, the cross sectional area of the wire needs to be at least 6 mm2
In case the cables are connected to a fuse box, the cables leading to the fuse
box shall be included in the calculation for the maximum voltage loss.
Caution!
For permanently live connection several legislation requirements
may apply depending on the country (additional isolator, circuit
breaker etc.).
Check for any legislation that may forbid the use of a heater when
the vehicle/boat etc. is unattended.
Make sure that only fuses with specified ratings are used.
Take care when the routing the cables, make sure that the insulation
of the electrical cables has not been damaged. Avoid placing the
cables near moving objects and machinery.
Make sure that any unused cables are well insulated.
Содержание Calaer 2 kW
Страница 1: ...Installation manual 2kW Calaer air heater 4kW Calaer air heater...
Страница 2: ......
Страница 4: ...2...
Страница 8: ...6...
Страница 12: ...10...
Страница 14: ...12...
Страница 15: ...6 Heaterdimensions 13 6 Heater dimensions Calaer 2 kW heater All measurements are given in millimeters mm...
Страница 16: ...6Heaterdimensions 14 Calaer 4 kW heater All measurements are given in millimeter mm...
Страница 17: ...6 Heaterdimensions 15...
Страница 18: ...16...
Страница 20: ...18...
Страница 22: ...20...
Страница 28: ...26...
Страница 38: ...36...
Страница 44: ...42...
Страница 48: ...13 Electricalsystem 46 13 4 Wiring diagram Figure Wiring diagram for Calaer 2 and 4 kW air heaters...
Страница 58: ......