MXA MXP MGP Rev4 - Operating Instructions

Page 11 / 64

connect the power supply cord through a conduit.

For use in swimming pools (not when persons are in 

the pool), garden ponds and similar places, a residual 

current device with IΔN not exceeding 30 mA must be 

installed in the supply circuit.

Install a device for disconnection from the mains 

(switch) with a contact separation of at least 3 mm in 

all poles.

With a three-phase motor install an overload protection 

device with curve D appropriate for the rated current 

of the pump.

Single-phase, are supplied with a capacitor connected 

to the terminals and (for 220-240 V - 50 Hz) with an 

incorporated thermal protector.

  ATTENTION:  When  the  pump  is  fed  by  a 

frequency  converter,  the  minimum  frequency 

should not fall below 25Hz and in any case the 

total head of the pump should never be lower 

than 3 m.

7.  STARTUP AND OPERATION
7.1.  Preliminary checks before start-up of the 

pump

Do not start-up the device in case of damaged parts.

7.2. First starting

OFF

 

  

  

ATTENTION: never run the pump dry. Start the 

pump after filling it completely with liquid.

When the pump is located above the water level 

(suction lift operation par. 13 fig. 2) or with a positive 

suction head which is too low (less than 1 m) to open 

the non-return valve, fill the pump through the priming 

hole (par. 13 fig. 4).

When the liquid level on the suction side is above 

the pump (inflow under positive  suction head par. 13 

fig. 1), fill the pump by opening the suction gate valve 

slowly and completely, keeping the delivery gate valve 

open to release the air.

Before starting, check that the shaft turns by hand. For 

this  purpose  use  the  screwdriver  notch  on  the  shaft 

end on the ventilation side.

When starting, with a three-phase motor, check 

that the direction of rotation  is  as  shown  by  the 

arrows on the lantern bracket. 

Otherwise, disconnect electrical power and reverse 

the connections of two phases.

Check that the pump works within its 

field  of  perfor-mance  and  that  the  absorbed  current 

shown on the name-plate is not exceeded. Otherwise 

adjust  the  delivery  gate  valve  or  the  setting  of  any 

pressure switches.

If a priming loss occurs (interruption of delivery flow) 

or if a pressure oscillation is indicated by the pressure 

gauge,  make  sure  all  the suction  pipe  couplings  are 

perfectly sealed and tighten the two sealed plugs on 

the pump casing. 

  Never  run  the  pump  for  more  than  five 

minutes with a closed gate valve.

Prolonged operation without a change

of water in the pump causes dangerous increases of 

temperature and pressure.

When the water is overheated due to prolonged 

operation  with  a  closed  port,  stop  the  pump  before 

opening the gate valve. 

To avoid any risk of danger to users and the creation of 

harmful thermal stress in the pump and system due to 

large temperature differentials, wait until the water has 

cooled inside the pump before starting again.

If  the  water  is  overheated  on  account  of  prolonged 

operation  with  a  non-primed  or  insufficiently  filled 

pump  (suction  lift  operation),  wait  until  cool  before 

opening the draining and filling plugs.

  Care must be taken when the pumped fluid 

has a high temperature. Do  not  touch  the  

fluid when its temperature is higher than  60 

°C. Do not touch the pump when the surface 

temperature is higher than 80 °C.

7.3. Automatic regulator IDROMAT

       (can be supplied on request)

For automatic control of starting/stopping of the pump 

when utilization points are opened/closed.

For protection of the pump:

•against dry running;

•against the risk of operation without water at the inlet 

(caused by a lack of water inflow in the inlet pipe under 

positive  suction  head,  by  a  non-immersed  suction 

pipe,  by  excessive  suction  lift  or  by  air  entering  the 

suction pipe);

•against operation with closed connection ports.

See installation examples par. 13 fig. 1, fig. 2.

7.4. Self-priming (Only for MXA)

(Capability  to  clear  the  air  in  the  suction  pipe  when 

starting with the pump located above the water 

level).

Conditions for self-priming:

•  suction  pipe  with  connections  perfectly  airtight  and 

properly immersed in the water to be lifted;

•  discharge pipe with a straight vertical free line above 

discharge port, before a non-return valve par. 13 fig. 

1.

•  pump    casing  completely  filled  with  clean  cold 

water  berfore starting. 

The  pump  is  not self-priming with liquids containing 

oil, alcohol or foaming substances.

The  check  valve  (par.  13  fig.  1)  prevents  reverse 

siphoning through the pump when the pump is stopped 

and retains water in the pump for the next start.

Without a foot valve or a check valve on the suction 

connection the filling operation must be repeated 

before each start-up.

  ATTENTION: avoid a prolonged operation 

with  unprimed  pump, without  water 

delivery from the completely opened outlet.

If the pump does not prime in 5 minutes: 

stop the motor, remove the priming plug 

and add more water.

If  necessary,  repeat  the  priming  operation  after  the 

pump has been first emptied and then completely filled 

with clean cold water.

7.5. Switch off of the pump

ON

  

  

  The  appliance  must  be  switch  off  every  time 

there are faults. (see troubleshooting).

The  product  is  designed  for  a  continuous  duty,    the 

switch  off  is  performed  by  disconnecting  the  power 

supply by means the expected disconnecting devices. 

(see paragraph “6.5 Electrical connection”).

8.  MAINTENANCE

Before any operations it's necessary to disconnect the 

power supply. 

If  required  ask  to  an  electrician  or  to  an  expert 

technician.

MXA MXP MGP Rev4.indd   11

13/07/17   17:03

Содержание MXP Series

Страница 1: ...orisontal flerstegs monoblock centrifugalpump Horizontale meertraps close coupled pompen MXP MGP MXA ISTRUZIONI ORIGINALI PER L USO Pagina 2 Italiano OPERATING INSTRUCTIONS Page 8 English BETRIEBSANLE...

Страница 2: ...tenze che devono essere rispettate altrimenti sono causa di danneggiamenti all apparecchio o compromettono la sicurezza del personale Informazioni ed avvertenze di carattere elettrico il cui mancato r...

Страница 3: ...0Y V3 50Hz cos X X X A XXXXXXXX S1 l cl X X kg X kW XHp S F VICENZA 1 2 3 4 5 6 7 8 9 10 16 15 14 13 12 11 3 CARATTERISTICHE TECNICHE 3 1 Dati tecnici Dimensioni di ingombro e pesi vedi catalogo Veloc...

Страница 4: ...Serrare i tubi o i raccordi solo quanto basta per assicurare la tenuta cap 13 fig 6 Un serraggio eccessivo pu danneggiare la pompa Al montaggio del tubo o raccordo tenere bloccata con controchiave la...

Страница 5: ...vitare pericoli per gli utilizzatori e dannose sollecitazioni termiche alla pompa ed all impianto dovute a elevati differenziali di temperatura attendere il raffreddamento dell acqua nella pompa prima...

Страница 6: ...nzionare brevemente la pompa con acqua pulita per rimuovere i depositi Quando la pompa rimane inattiva deve essere svuotata completamente se esiste il pericolo di gelo cap 13 fig 5 Prima di rimettere...

Страница 7: ...non a tenuta e sigillare in modo pi efficace la connessione b Pulire o sostituire la valvola di fondo e impiegare un tubo di aspirazione idoneo all applicazione c Pulire il filtro se necessario sosti...

Страница 8: ...d otherwise there is a risk that the machine could damage or compromise personnel safety The failure to observe electrical information and warnings could damage the machine or compromise personnel saf...

Страница 9: ...late pump Made in Italy MONTORSO XXXXXXX Q min max X X m3 h XXXXXXX H max min X X m IP XX n XXXX min 220 380Y V3 50Hz cos X X X A XXXXXXXX S1 l cl X X kg X kW XHp S F VICENZA 1 2 3 4 5 6 7 8 9 10 16 1...

Страница 10: ...ecured to rest clamps so that they do not transmit stress strain or vibrations to the pump par 13 fig 3 Tighten the pipes or union coupling to the extent sufficient to ensure a tight seal par 13 fig 6...

Страница 11: ...sed port stop the pump before opening the gate valve To avoid any risk of danger to users and the creation of harmful thermal stress in the pump and system due to large temperature differentials wait...

Страница 12: ...completely if there is a risk of freezing par 13 fig 5 Before restarting the unit check that the shaft is not jammed and fill the pump casing completely with liquid 8 2 Dismantling the system Close t...

Страница 13: ...cessary replace it See point 2a also 4 Insufficient flow 4a Pipes and accessories with diameter too small causing excessive loss of head 4b Presence of deposits or solid bodies in the internal passage...

Страница 14: ...nden Bedeutungen im Folgenden aufgelistet Informationen und Hinweise welche zu beachten sind um Besch digungen an dem Ger t oder M ngel an der Sicherheit des Personals zu vermeiden Informationen und H...

Страница 15: ...X m3 h XXXXXXX H max min X X m IP XX n XXXX min 220 380Y V3 50Hz cos X X X A XXXXXXXX S1 l cl X X kg X kW XHp S F VICENZA 1 2 3 4 5 6 7 8 9 10 16 15 14 13 12 11 3 TECHNISCHE MERKMALE 3 1 Technische D...

Страница 16: ...hellen abzufangen und spannungsfrei an die Pumpe anzuschlie en Kap 13 Abb 3 Die Rohre bzw die Anschlu stutzen sind nur sofest anzuschrauben wie es f r die Dichtigkeit reicht Kap 13 Abb 6 berm ige Dreh...

Страница 17: ...chieber berhitzt ist Pumpe ausschalten bevor Absperrschieber ge ffnet wird Um Gefahren f r Personen und sch dliche thermische Belastungen f r die Pumpe und die Anlage wegen zu gro er Temperaturuntersc...

Страница 18: ...r durchzusp len Wird die Pumpe nicht eingesetzt so mu sie bei Frostgefahr vollst ndig entleert werden Kap 13 Abb 5 Vor Wiederinbetriebnahme ist zu kontrollieren ob die Pumpe durch Verunreinigungen blo...

Страница 19: ...e auch Punkt 2a 4 Zu geringe F rdermenge 4a Verrohrung und Armaturen mit zu kleiner Nennweite verusachen zu gro e Verluste 4b Feststoffe oder Ablagerungen im Laufrad oder Pumpengeh use 4c Laufrad defe...

Страница 20: ...la cause de dommages l appareil et compromettent la s curit du personnel Informations et avertissements de caract re lectrique qui s ils ne sont pas respect s peuvent causer des dommages l appareil e...

Страница 21: ...S F VICENZA 1 2 3 4 5 6 7 8 9 10 16 15 14 13 12 11 3 CARACT RISTIQUES TECHNIQUES 3 1 Donn es techniques Dimensions d encombrement et poids voir catalogue technique Vitesse nominale 2900 3450 rpm Prot...

Страница 22: ...uyaux ou les raccords seulement de mani re suffisante pour ass rer l tanch it Un serrage excessif peut endommager la pompe Au montage du tuyau ou raccord tenir bloqu l orifice sur le corps de pompe pa...

Страница 23: ...viter tout danger aux utilisateurs ainsi que des sollicitations thermiques sur la pompe et l installation en raison des diff rentiels de temp rature lev s attendre le refroidissement de l eau dans la...

Страница 24: ...t s il existe un danger de gel Chap 13 fig 5 Avant de remettre en marche la pompe contr ler que l arbre ne soit pas bloqu par des incrustations ou par d autres causes et remplir compl tement de liquid...

Страница 25: ...ter aussi le paragraphe 10 2a 4 D bit insuffisant 4a Tuyaux et accessoires avec un diam tre trop petit entra nant des pertes de charge 4b Pr sence de d p ts et de corps trangers dans l int rieur du pa...

Страница 26: ...personal Informaci n y advertencias de naturaleza el ctrica El incumplimiento con ellas puede da ar el aparato o comprometer la seguridad del personal i Indicaciones de notas y advertencias para el ma...

Страница 27: ...max min X X m IP XX n XXXX min 220 380Y V3 50Hz cos X X X A XXXXXXXX S1 l cl X X kg X kW XHp S F VICENZA 1 2 3 4 5 6 7 8 9 10 16 15 14 13 12 11 3 CARACTER STICAS T CNICAS 3 1 Datos t cnicos Dimension...

Страница 28: ...13 fig 3 Apretar los tubos y los racords solo cuando se tenga asegurado la estanqueidad cap 13 fig 6 Un excesivo apriete puede da ar la bomba El di metro interior de los tubos no debe ser inferior al...

Страница 29: ...antes de abrir la compuerta Para evitar peligros para los usuarios y da osas cargas t rmicas a la bomba y a la instalaci n debido a elevadas diferenciales de temperaturas esperar el enfriamiento del...

Страница 30: ...igro de heladas esta debe de ser vaciada completamente cap 13 fig 5 Antes de poner en marcha el motor controlar que el eje no esta bloqueado por incrustaciones o por otras causas y llenar de l quido l...

Страница 31: ...licaci n c Limpiar el filtro si es necesario sustituirlo Ver tambi n el punto 2a 4 Caudal insuficiente a Tuber a y accesorios con di metro demasiado peque o que provocan excesivas perdidas de carga b...

Страница 32: ...et leda till skador p apparaten eller ventyra personalens s kerhet Information och varningstexter av elektriskt slag som kan leda till skador p apparaten eller ventyra personalens s kerhet om de inte...

Страница 33: ...XX n XXXX min 220 380Y V3 50Hz cos X X X A XXXXXXXX S1 l cl X X kg X kW XHp S F VICENZA 1 2 3 4 5 6 7 8 9 10 16 15 14 13 12 11 3 TEKNISKA EGENSKAPER 3 1 Tekniska data Totalm tt och vikt se den teknis...

Страница 34: ...ll av frig ng fyllning dr nering av pumphuset samt att eventuell spillning av v tskan f r sanering skall kunna utf ras 6 4 1 R rledningar Se till att r rledningarna r rengjorda f re inkoppling VARNING...

Страница 35: ...mperatur i pumphuset N r v tskan r verhettad genom k rning mot st ngd ventil stoppa pumpen f re ppnandet av ventilen p tryckledningen F r att unvika skador fr n skiftande v tsketemperatur v nta tills...

Страница 36: ...pen tillf lligt pumpat f rorenad v tska partiklar skall denna tappas ur samt fyllas och k ras med ren v tska Om pumpen ej anv nds m ste den t mmas helt om det f religger frysrisk kap 13 fig 5 F re ter...

Страница 37: ...eter medf r stora f rluster 4b N rvaro av f roreningar i pumphjulet 4c Pumphjul igensatt 4d Slitet pumphus eller pumphjul 4e verskriden viskositet p v tskan om annat n vatten 4f Felaktig rotationsrikt...

Страница 38: ...j schade aan het apparaat of brengen de veiligheid van het personeel in gevaar Informatieenwaarschuwingenvanelektrischeaard die zo ze worden genegeerd een beschadiging van het apparaat tot gevolg kunn...

Страница 39: ...1 l cl X X kg X kW XHp S F VICENZA 1 2 3 4 5 6 7 8 9 10 16 15 14 13 12 11 3 TECHNISCHE EIGENSCHAPPEN 3 1 Technische gegevens Afmetingen en gewicht zie technische catalogus Nominale snelheid 2900 3450...

Страница 40: ...ning in het leidingwerk gemonteerd zit par 13 fig 3 Eventuele trillingen in het leidingwerk dienen de pomp niet te bereiken Bevestig de leidingen of koppelingen zodanig dat er geen lekkage optreedt pa...

Страница 41: ...oververhit is geraakt door langdurig niet te hebben aangezogen of door een onvoldoende gevuld pomphuis dient de pomp na afschakelen volledig te zijn afgekoeld alvorens de persleiding of aftappluggen...

Страница 42: ...g draaien met schoon water om afzettingen af te voeren In geval van verwachte stilstand voor langere periode of vorst pomp volledig aftappen par 13 fig 5 Alvorens de unit weer in bedrijf te stellen co...

Страница 43: ...adequaat 3b Maak de voetklep schoon of vervang die gebruik de juiste zuigleiding voor de toepassing 3c Maak het filter schoon of vervang het filter zie punt 2b 4 Onvoldoen capaciteit 4a Te kleine lei...

Страница 44: ...DA S p A 1 Calpeda SpA 2 3 8 3 1 6 5 6 5 1 1 i E E OFF ON 1 2 Calpeda S p A Via Roggia di Mezzo 39 36050 Montorso Vicentino Vicenza Italia www calpeda it 1 3 i 1 44 2 45 3 45 4 45 5 46 6 46 7 47 8 48...

Страница 45: ...3 4 5 6 7 8 9 T 10 11 12 cos 13 14 15 16 Made in Italy MONTORSO XXXXXXX Q min max X X m3 h XXXXXXX H max min X X m IP XX n XXXX min 220 380Y V3 50Hz cos X X X A XXXXXXXX S1 l cl X X kg X kW XHp S F V...

Страница 46: ...GR 46 64 MXA MXP MGP Rev4 4 5 5 5 1 25 kg 6 6 1 6 2 3 2 6 3 i 6 4 13 1 2 6 4 1 13 3 13 6 6 4 2 10m 4 m3 h G 1 1 4 D 32 13 2 MXA 13 1 6 4 3 15 m 6 5 OFF L...

Страница 47: ...GR MXA MXP MGP Rev4 47 64 07 RN F 13 2 TAB 1 30mA 3 mm D 220 240V inverter 25 3 7 7 1 7 2 OFF 13 2 1m 13 4 13 1 5 60 C 80 C 7 3 IDROMAT 13 1 2 7 4 MXA 13 1 13 1 5 7 5 OFF ON 6 5...

Страница 48: ...ring 14 20 O ring 14 24 16 00 16 14 16 15 16 16 16 17 20 00 22 12 O ring 22 16 O ring 25 01 25 02 25 05 25 10 Washer for missing impeller 25 11 First stage spacer 28 00 28 04 28 08 34 00 Casing cover...

Страница 49: ...49 64 12 OFF 1 1a 1b 1c 1d 1e 1f 1a 1b 1c 1d a c 1e 1f 2 2a 2b 2c 2a 2b 2c 3 3a 3b 3c 3a 3b 3c 2b 4 4a 4b 4c 4d 4e 4f 4g 4h 4a 4b 4c 4d 4e 4f 4g 4h 5 5a 5b 5c 5d 5e 5f 5a 5b 5c 5d 5e 5f 6 6a 6b 6c 6d...

Страница 50: ...DAS P A 1 Calpeda S p A 2 3 CE 8 3 1 6 5 6 5 1 1 i OFF ON 1 2 Calpeda S p A Via Roggia di Mezzo 39 36050 Montorso Vicentino Vicenza Italia www calpeda it 1 3 i 1 50 2 51 3 51 4 51 5 52 6 6 52 7 53 8 5...

Страница 51: ...2 3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Made in Italy MONTORSO XXXXXXX Q min max X X m3 h XXXXXXX H max min X X m IP XX n XXXX min 220 380Y V3 50Hz cos X X X A XXXXXXXX S1 l cl X X kg X kW XHp S F...

Страница 52: ...RU C 52 64 MXA MXP MGP Rev4 4 5 5 5 1 25 6 6 6 1 6 1 6 2 3 2 6 3 i 6 4 13 1 2 6 4 1 13 3 13 6 6 4 2 10 4 G 1 1 4 DN 32 13 2 MXA 13 1 6 4 3 15 6 5 OFF 07 RN F 13 2 TAB 1 I N 30 mA 3...

Страница 53: ...RU MXA MXP MGP Rev4 C 53 64 D 50 220 240 25 3 7 7 1 7 2 OFF 13 2 1 13 4 13 1 5 K 60 C 80 C 7 3 IDROMAT 13 1 2 7 4 MXA 1 5 7 5 ON 6 5 8...

Страница 54: ...1 Calpeda S p A 11 Nr 14 00 14 04 14 06 14 12 14 16 14 20 14 24 16 00 16 14 16 15 16 16 16 17 20 00 22 12 22 16 25 01 25 02 25 05 25 10 25 11 28 00 28 04 28 08 34 00 36 00 36 51 2 46 00 64 15 70 00 7...

Страница 55: ...RU MXA MXP MGP Rev4 C 55 64 12 OFF 1 2 a a 3 a a 2 a 4 a a 5 a a 4 6 a 5 6 6 6...

Страница 56: ...5 1 1 i OFF ON 1 2 CALPEDA S P A Via Roggia di Mezzo 39 36050 Montorso Vicentino Vicenza Italia www calpeda it 1 3 i 1 4 i 1 5 Calpeda S p A 1 2 2 MXP AISI304 PPO GF20 MGP PPO GF20 MXA AISI304 PPO GF2...

Страница 57: ...n max X X m3 h XXXXXXX H max min X X m IP XX n XXXX min 220 380Y V3 50Hz cos X X X A XXXXXXXX S1 l cl X X kg X kW XHp S F VICENZA 1 2 3 4 5 6 7 8 9 10 16 15 14 13 12 11 3 3 1 2900 3450rpm IP54 240V 1...

Страница 58: ...58 64 MXA MXP MGP Rev4 6 4 2 10m 4M3 H G1 1 4 DN32 2 1 6 4 3 _ 15m 6 5 OFF H07RN F 13 2 30 3mm 220 240V 50Hz 25Hz 3m 7 7 1 7 2 OFF 13 3 1m 13 4 13 1 5 60 C 80 C 7 3 IDROMAT v 1 2 7 4 MXA 1 1 5...

Страница 59: ...CALPEDA S P A 11 14 00 14 04 14 06 O 14 12 14 16 O 14 20 O 14 24 16 00 16 14 15 15 16 16 O 16 17 20 00 22 12 22 16 25 01 25 02 25 05 25 10 25 11 28 00 28 04 28 08 34 00 36 00 36 51 46 00 64 15 70 00 7...

Страница 60: ...1 1a 1b 1c 1d 1e 1f 1a 1b 1c 1d a c 1e 2 1f 2 2a 2b 2c 2a 2b 2c 3 3a 3b 3c 3a 3b 3c 2a 4 4a 4b 4c 4d 4e 4f 4g 4h 4a 4b 4c 4d 4e 4f 4g 4h 5 5a 5b 5c 5d 5e 5f 5g 5a 5b 5c 5d 5e 4g 5f 5g 6 6a 6b 6c 6d 6a...

Страница 61: ...sage Llenado Fyllning Vullen Fig 5 Scarico Draining Entleerung Vidange Vaciado Avtappning Aftappen Fig 2 Funzionamento in aspirazione Suction lift operation Saugbetrieb Fonctionnement en aspiration Fu...

Страница 62: ...066 98 08 82 00 76 20 76 16 90 00 90 04 MXA 205 MXA 405 82 04 0 5 m h 4 93 312 G 1 DN 25 i 28 mm G 1 1 4 DN 32 i 36 mm MXA 205 405 Hs Hs MXA 205 203 2 0 4 404 4 0 5 403 404 204 100 200 450 600 203 10...

Страница 63: ...403 25 01 28 00 25 10 64 15 25 11 25 11 25 11 25 10 64 15 28 08 MXP 403 MXP 403 60 MXP 202 MXP 402 MXP 202 60 MXP 402 60 MXP 201 60 MXP 401 60 MXP 203 60 MXP 402 60 64 15 25 10 MXP 403 60 2 MXP 205 MX...

Страница 64: ...vist p typeskiltet er fremstillet i overensstemmelse med bestemmelserne i Direktiv 2006 42 EC 2009 125 EC 2014 30 EU 2014 35 EU og er i overensstemmelse med de heri indeholdte standarder Kommissionen...

Отзывы: