EN
Page 12 / 72
E-MPSM Rev1 - Operating Instructions
Through this button you have access to the
product programming parameters. If you
already are on the programming functions,
by pushing this button you go up on the
menu
Through this button you have access to
programming parameters. If you changed
a parameter, by pushing this button you
can confirm the indicated value.
Through this button you can reset the
errors.
Through this button you can decrease
parameters or to change the visualized
parameter.
Through this button you can increase
parameters or to change the visualized
parameter.
4. SAFETY
4.1. General provisions
Before using the product it is necessary to
know all the safety indications.
Carefully read all operating instructions and the
indications defined for the different steps: from
transportation to disposal.
The specialized technicians must carefully comply
with all applicable standards and laws, including local
regulations of the country where the pump is sold.
The device has been built in conformity with the current
safety laws. The improper use could damage people,
animals and objects.
The manufacturer declines any liability in the event of
damage due to improper use or use under conditions
other than those indicated on the name-plate and in
these instructions.
i
Follow the routine maintenance schedules and
the promptly replace damaged parts, this will
allows the device to work in the best conditions.
Use only original spare parts provided from Calpeda
S.p.A or from an authorized distributor.
Don’t remove or change the labels placed on
the device.
Do not start the device in case of defects or damaged
parts.
Maintenance operations, requiring full or partial
disassembly of the device, must be done only
after disconnection from the supply.
Pollution of the liquid could occur due to
leakage of lubricants.
4.2. Safety devices
The device has an external case that prevents any
contact with internal parts.
4.2.1. Protection devices
The device is provided with a double shaft seal with
interposed oil chamber, ensuring motor is separated
from water, eliminating potential electrical risks, and
ensuring protection from accidental dry running.
The product is provided with a screen that avoids the
accidental contact with dangerous parts of the impeller.
4.3. Residual risks
The appliance, designed for use, when used in-line
with the design and safety rules, doesn’t have residual
risks.
4.4. Information and Safety signals
For this kind of product there will not be any signals
on the product.
4.5. Individual protection devices
During installation, starting and maintenance it is
suggested to the authorized operators to consider
the use of individual protection devices suitable for
described activities.
During ordinary and extraordinary maintenance
interventions, safety gloves are required.
Signal
individual protection device
HAND PROTECTION
(gloves for protection against chemical,
thermal and mechanical risks).
5. TRANSPORTATION AND HANDLING
The product is packed to maintain the content intact.
During transportation avoid to stack excessive weights.
Ensure that during the transportation the box cannot
move.
It is not necessary to use any special vehicle to
transport the packaged device.
The transport vehicles must comply, for the weight and
dimensions, with the chosen product (see technical
catalogue dimensions and weights).
5.1. Handling
Handle with care, the packages must not receive
impacts.
Avoid to impact onto the package materials that could
damage the pump.
If the weight exceeds 25 kg the package must be
handled by two person at the same time.
6. INSTALLATION
6.1. Dimensions
For the dimensions of the device (see technical
catalogue).
6.2. Ambient requirements and installation site
dimensions
The customer has to prepare the installation site in
order to guarantee the right installation and in order to
fulfill the device requirements (electrical supply, etc...).
It's Absolutely forbidden to install the machine in an
environment with potentially explosive atmosphere.
6.3. Unpacking
i
Inspect the device in order to check any
damages which may have occurred during
transportation.
Package material, once removed, must be discarded/
recycled according to local laws of the destination
country.
It's absolutely forbidden to handle the product
by means of the electric power cable. It is
recommended to lift the pump from the motor
end and place it vertically on the filter, then
lower it down in the place chosen.
Содержание e-idos E-MPSM
Страница 57: ...RU E MPSM Rev1 C 57 72 13 OFF 1 195 Er03 2 a 3 a a 2 a 4 UP01 UP01 5 a 6 a a 7 a a 8 a 15 30 240 2 Er05 9 a a...
Страница 69: ...E MPSM Rev1 69 72...
Страница 70: ...70 72 E MPSM Rev1...
Страница 71: ...E MPSM Rev1 71 72...