Pressure Regulator Location
Remove rear cover to expose pressure regulator.
Regulator Cover
Gas Supply Location
Gas supply must be located in the area shown. Gas
connection must not interfere with the electrical
connection.
A
B
C
D
A
B
A—26 inches
B—20 inches
C—2¼ inches
D—4 inches
Gas Supply Location
Gas Supply Pressure
CAUTION
!
To avoid property damage, maximum gas supply
pressure must not exceed 14" WCP.
• Appliance and individual shut-off valve must be
disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in
excess of ½ psig (3.5kPa) (14" WCP).
• Appliance must be isolated from gas supply piping
system by closing manual shut-off valve during any
pressure testing of the gas supply piping system at
test pressures equal to or less than ½ psig (3.5kPa)
(14" WCP).
• Gas supply pressure for checking regulator setting
must be at least 1" WCP above manifold pressure
shown on rating label.
Installation
(cont’d)