6
IMPORTANT SAFETY NOTICE
Do not attempt to operate the heater until you have read and understood the user instruction manual and this safety notice.
Failure to do so could result in serious property damage,
personal injury or death
•
The heater is only suitable for use with
BUTANE GAS at 28mbar
operating pressure and must not be connected to any other type of gas supply.
•
DO NOT allow combustible materials to be placed directly on to, or be stored close to the heater, and do not leave unattended when in use
•
The minimum room size to use this heater in is
64 cubic metres
and must have a free ventilation directly from outside into the room of
80 cm squared area.
•
The heater must
NOT BE USED
in a bedroom, bathroom, shower area, garage or in any other room or space which does not have
permanent ventilation of 80 cm squared area
•
DO NOT use heater in an open plan type building or dwelling where there is no separation between the main living area and bedrooms
•
Always check that the heater is burning cleanly. A build up of dust, debris or any other foreign matter in or around the burner will effect the
safe use of the appliance. See page 2 of the maintenance booklet for correct flame burning pattern.
•
Should you become aware of a smell, signs of discolouration or sooting.
TURN OFF IMMEDIATELY
and have the heater examined and
serviced by a qualified gas technician.
•
Should you become aware of a stuffy atmosphere or a lack of fresh air in the room do check the room size is suitable and that there is
adequate ventilation.
•
The heater is fitted with an oxygen depletion sensing device which is designed to turn off the heater if the oxygen level in the room drops
below a safe level.
•
If the heater turns off automatically it is very important to check that there is proper ventilation and that the heater is burning cleanly and has
not become contaminated with dust or debris or some other foreign matter. Check there is adequate ventilation and that the heater is burning correctly
before using it again.
•
This heater must be examined and serviced by a qualified gas technician annually or after a prolonged period of non-use.
•
Your local gas supplier can be of help in this regard or you can call the Calor helpline UK (0800662663) Ireland (01 4505000) to get details of
service agents in your area.
•
When the heater is used for the first time you will notice a smell, this is normal because the appliance is new. Operate in a very well ventilated
area for about four hours after which the smell should disappear. If the smell persists please contact our helpline.
•
If the heater is used in an environment which is frequented by children or those requiring special care must always be protected with a guard.
If you have any queries or questions please don’t hesitate to contact
Universal Innovations Ltd on our helpline. Tel: 00353 1 2873797