background image

1

LLEEAAKK TTEESSTTIIN

NGG

You must leak test the unit at the beginning of every heating season and in the event that you smell gas, or after

a prolonged period on non-use.

To perform a leak test.

1.

Mix 50% water 50% soap solution.

2.

Attach the regulator to the gas cylinder. (Note: the regulator must be in the off position when its 

connected to the cylinder)

3.

Apply the soap solution to all areas of the regulator to gas cylinder connection, regulator to hose 

connection, hose to appliance connection, base of valve.

4.

If bubbles appear there is a leak

Contact the Customer Service He353 (01) 2873797

5.

Turn the regulator to the on position, repeat step 3, if bubbles appear there is a leak.

Contact the Customer Service He353 (01) 2873797

Regulator to Gas

Cylinder Connection

Regulator to Hose

Connection

Hose to Appliance

Connection

Содержание Provence

Страница 1: ...pliance and if not operating or functioning correctly can cause serious injury damage to your home or even death to you family members or friends This heater must be serviced by a qualified gas techni...

Страница 2: ...ition when its connected to the cylinder 3 Apply the soap solution to all areas of the regulator to gas cylinder connection regulator to hose connection hose to appliance connection base of valve 4 If...

Страница 3: ...uld rise just above the coals when on high setting See image 1 A build up of dust debris or any other foreign matter in or around the burner or air inlets will affect safe use of the appliance and cau...

Страница 4: ...AL LI IF FI IE ED D G GA AS S T TE EC CH HN NI IC CI IA AN N 1 Remove the front casting by unscrewing the 4 wing nuts located inside the cylinder chamber and lifting the front casting away 2 Check th...

Страница 5: ...y using pressurised air blow out the burner First through the primary air inlet and then through the top burner mesh 5 Clean all other parts of the heater with a damp non abrasive cloth Soft brush on...

Страница 6: ...to main burner and ODS 3 Ignite unit and ensure flame picture is correct see below A flame picture as shown on iim ma ag ge e 2 2 o on n p pa ag ge e 2 2 indicates incomplete combustion Repeat cleanin...

Страница 7: ...amined and serviced by a qualified gas technician Should you become aware of a stuffy atmosphere or a lack of fresh air in the room do check the room size is suitable and that there is adequate ventil...

Отзывы: