1
LLEEAAKK TTEESSTTIIN
NGG
You must leak test the unit at the beginning of every heating season and in the event that you smell gas, or after
a prolonged period on non-use.
To perform a leak test.
1.
Mix 50% water 50% soap solution.
2.
Attach the regulator to the gas cylinder. (Note: the regulator must be in the off position when its
connected to the cylinder)
3.
Apply the soap solution to all areas of the regulator to gas cylinder connection, regulator to hose
connection, hose to appliance connection, base of valve.
4.
If bubbles appear there is a leak
Contact the Customer Service He353 (01) 2873797
5.
Turn the regulator to the on position, repeat step 3, if bubbles appear there is a leak.
Contact the Customer Service He353 (01) 2873797
Regulator to Gas
Cylinder Connection
Regulator to Hose
Connection
Hose to Appliance
Connection