Page 14
necessary to replace the lid gasket to ensure a reliable steam-tight
seal.
Note: the elements have a permanent ‘Live’ feed, and the
‘Neutrals’ are switched.
Printed Circuit Board replacement (PCB)
In the event of a PCB failing and a replacement being required, full
instructions will be supplied. It is important to note however, that the
Triac PCB’s must be securely mounted against the copper heat-
sinks to ensure reliable heat dissipation. Heat transfer compound is
also supplied with all replacement circuit boards.
Adjusting the Water Temperature Set Point
The temperature potentiometer (Pot) is pre-set at Calomax and
will only require adjustment in exceptional circumstances. Contact
Calomax for advice.
Water boils at different temperatures depending on barometric
pressure. The temperature should not be tuned higher than 98
°C
, or
over boiling may occur during low barometric pressure conditions,
causing the unit to trip the overheat cut-out device.