Page 7
The element(s) may be also be energized at the same time. If water is
drawn from the machine but boiling water is still available, the Wait/Ready
light will be illuminated solid yellow. If full draw off capacity is removed the
boiler may cool, indicated by the Wait/Ready light flashing yellow.
Note:
When the green service indicator light on the front of the boiler is showing
solid colour, the header tank sensor has been starved of water for in
excess of 30 seconds and the bottom thermistor has been disabled. To
reinstate normal operation the water supply needs to be re-applied.
If the service indicator light flashes, this indicates that the water level has
reached the high level sensor and the likelihood is that the normal level
sensor requires de-scaling, or the machine has over-filled due to debris
trapped in the solenoid valve.The debris can be removed by drawing plenty
of water from the dispense tap, causing the solenoid valve to operate and
flush out the obstruction. The machine will reset itself once the problem has
cleared. If this does not rectify the problem, turn off the water supply and
remove the flexible hose to check for debris in the valve’s filter. When the
service light is flashing, the element is disabled and the boiler may cool.
For further assistance, contact our service department on 0113 249 6681,
or e-mail [email protected].
The production of scale is a natural phenomenon and commonly occurs
in hot water systems. The nature of the scale produced and its rate of
formation varies widely throughout the country.
To ensure continuous, reliable operation, the boiler should be regularly de-
scaled by a suitably qualified engineer. Suitable chemical de-scalants must
only be used if the manufacturers recommendations are strictly adhered
to. This is to prevent health and safety issues, taste problems and potential
damage to the appliance. Misuse of such chemicals is not covered by the
product warranty.
The Kudos range of boilers benefit from an integral scale inhibitor.
This
is not
a scale eliminator and its effects will differ according to the
water
quality in your area. To ensure trouble free operation, periodically check
for scale inside the boiling chamber. The production of scale is a natural
phenomenon and some de-scaling may be required within the first 12
months. This is not covered under the products warranty as it is not a fault.
SCALE