Page 5
MODEL
A
B
C
DRY
WEIGHT
WORKING
WEIGHT
KUDOS 6
KUDOS 9
mm 745 380 275
21 Kg
48 Kg
ALL DIMENSIONS ARE APPROXIMATE
DIMENSIONS AND WEIGHTS
C
B
A
BEFORE CONNECTING, THE SUPPLY PIPE MUST BE
THOROUGHLY FLUSHED OUT TO ENSURE THAT FOREIGN
MATTER DOES NOT BLOCK OR ENTER THE SOLENOID VALVE
The boiler must be connected to a potable water supply using the
food grade hose provided, in a manner which complies with UK water
regulations. The hose should be connected to a ½” (15mm) drinking
water supply via an appropriate isolating valve. The supply must
provide a constant pressure of between 20 KPa and 1000 KPa (0.2 to
10 Bar).
If the water supply contains excessive solids in suspension it is
recommended that a fine mesh “in line” water filter is fitted in the pipe
VENT & OVERFLOW
The vent / overflow pipe must be extended and laid with a
continuous
fall
,
discharging to a safe and visible point. The pipe should not be
directly connected to a closed waste, as taste problems may occur and
should never be allowed to become blocked or restricted.15mm copper
or ‘Speedfit’ pipe should be used. If the machine is operated without