13
Use DIP Switches
Figure 15 DIP switch
1.
TIMER: 1-60S Timer: Auto activated to close gate upon set time ( 1~ 60 seconds).
2.
RADIO: Remote control radio receiver, allow remote control to close gate without timer
activation.
3.
OSC: Remote control priority. Allow remote control to direct gate movement whenever
gate is moving in any direction. First signal stop gate, second signal move gate to opposite
direction.
4. LOCK: Use for lock or unlock gate. When switch ON, The LOCK in Control board (Left edge
Figure 12) will be available to output 115 V power.
5. 1 PASS: Anti-tailgating system. It corresponds to underground safety loop. when ON
selected, Once the vehicle has cleared safe loop outside of property, gate start to close
immediately without opening to limit. If second vehicle across loop at this time, gate will stop.
The second vehicle must get off the loop and then gate continue to close completely.
6. SLAVE: Secondary operator activation.
7. BRAKE: Use to slow down movement of gate when it is reaching limit of open or close.
8. OPEB L/R: Choose gate open direction Left or Right
Содержание CM-5-ACFP