CALIFORNIA ACCENT LIGHTING, INC.
2034 E. Lincoln Ave. #431, Anaheim, CA 92806
ph. 800.921.CALI (2254) or 714.535-7900 \ fx. 714.535.7902
[email protected] \ calilighting.com
© CALI. All rights reserved. CALI reserves the right to make changes or withdraw specifications without prior notice.
Installation Instructions
lip
LEDs
™
LLED
8600-RME
19 of 21
Troubleshooting
TROUBLESHOOT
• Do not reset breaker multiple times.
• If the unit is overloaded the breaker will trip, shutting off the
transformer and lights.
• If the breaker reset button has been held down by hand or any type
of pressure (example: duct tape), or if the breaker has been reset
multiple times without troubleshooting, the unit will:
- Burn the transformer bobbin
- Burn the thermal or magnetic breaker
- Burn the primary or secondary wires due to high amperage caused
by overload and/ or short circuit in line which will not allow the
breaker to reset
- Damage the lighting
1.
Turn off power before beginning. Check for any twisting or damage to
the circuit in the LED lightstrip. If there is excessive damage and
circuit is broken, the lightstrip must be replaced.
2.
Check for metal particles or other foreign objects causing the short.
3.
Check if cut is clean and not frayed, causing positive and negative
copper pads to touch.
4.
Ensure the run is not too long and overlapping.
5.
Ensure copper pads are not making contact with aluminum extrusion.
6.
Check wiring diagram.
7.
Reset power to controller.
Frayed end
Copper pads touching extrusion
Foreign object
Lightstrip overlapping extrusion
Metal flakes
Damaged lightstrip
Twisted lightstrip
Torn lightstrip
Frayed end
Copper pads touching extrusion
Foreign object
Lightstrip overlapping extrusion
Metal flakes
Damaged lightstrip
Twisted lightstrip
Torn lightstrip
Frayed end
Copper pads touching extrusion
Foreign object
Lightstrip overlapping extrusion
Metal flakes
Damaged lightstrip
Twisted lightstrip
Torn lightstrip
Frayed end
Copper pads touching extrusion
Foreign object
Lightstrip overlapping extrusion
Metal flakes
Damaged lightstrip
Twisted lightstrip
Torn lightstrip
Frayed end
Copper pads touching extrusion
Foreign object
Lightstrip overlapping extrusion
Metal flakes
Damaged lightstrip
Twisted lightstrip
Torn lightstrip
Frayed end
Copper pads touching extrusion
Foreign object
Lightstrip overlapping extrusion
Metal flakes
Damaged lightstrip
Twisted lightstrip
Torn lightstrip