Operating Instructions
Uniprep 7 Rotary Scraping Tool
07
Removal After Completion
1. Use the Cutting arm T screw to release blade spring tension.
2. Lift and lock scraper arm using cutter arm release knob.
3. Ensure the angle relief wing nut is tightened and does not allow the
tool tip cartridge to pivot.
4. Release the feed screw drive knob and slide out feed screw and
scraper arm and crank handle.
5. Separate scraper arm from crank handle using Crank Arm T Screw.
6. Use spanner clockwise to remove expanding body.
7. Ensure all parts are clean and dry.
8. Put all parts away in transport cases to protect them.
Storage
IMPORTANT! When not in use always:
1. Store the tool in the transport cases, ensure it is clean and dry
before storage.
2. Ensure cutter tip will not get damaged when transporting or storing
as this can severely limit the quality of the scrape.
Routine Maintenance
1. Check for correct movement and operation and lubricate moving
parts at regular intervals before using.
2. It is important to ensure all component parts are present and in
serviceable condition. In addition, the condition of the cutting /
peeling tip should be checked for damage or excessive wearing.
3. The cutter tip can be replaced. Spares are indicated in the parts
diagram.