Bandwidth
Bit Rate
140-5018-60x
140-5048-40x
140-5048-60x
RX Frequencies
142 - 174
406.125 – 470.000
450.000 - 511.975
MHz
MHz
ETSI Mode Useable
Sensitivity
@ 10
-2
Bit Error
Rate (BER)
Typical /
Max
12.5 kHz (ETSI)
8 kbps
16 kbps
24 kbps
-111 /
-108
-104 /
-101
-96 /
-92
-111 /
-108
-104 /
-101
-96 /
-92
dBm
dBm
dBm
25kHz (ETSI)
16 kbps
32 kbps
48kbps
-110 /
-107
-103 /
-100
-96 /
-92
-110 /
-107
-103 /
-100
-96 /
-92
dBm
dBm
dBm
Adjacent Channel
Rejection (min)
6.25 kHz
45
45
45
--
dB
12.5 kHz
60
60
60
60
dB
25 kHz
70
70
70
70
dB
50 kHz
75
75
75
75
dB
Spurious Response
Rejection
All
> 75 dB
dB
Intermodulation
Rejection
All
> 75 dB
dB
TX to RX Time
All
< 1 ms
5 ms (ETSI Versions)
ms
Channel Switching
Time
All
< 15ms (Band-End to Band-End)
ms
Receive Input
Power
All
17 dBm (50mW) max.
dBm
Connectors
Antenna Connector
TNC female (Tx/Rx)
Serial Setup Port
DE-9F
Serial Terminal Server
DE-9F
Ethernet RJ-45
10 BaseT auto-MDIX
Power - I/O
Power Header
Power Plug
DRL p/n 415-7108-113
(Weidmüller p/n 1615550000)
4 Pin, 3.5mm, Power Header
DRL p/n 897-5008-010
(Weidmüller p/n 1639260000)
4 Pin, 3.5mm, Power Plug
Cable: 60 inches
Connections: Fan Output, Ground, Power,
Enable