SECTION 7
um_tslm rev3.doc
Page 50 of 62
7.2.11 User Test
Figure 7.13 User Test Utility Screen
The User Test utility is an Offline function and requires suspension of network operation.
Diagnostics:
User Test diagnostic parameters include:
Select
Select allows the user to choose Current, Low or High Diagnostics. Current shows the value
of the last requested parameters. Low or High displays the lowest or highest value of the
parameters since the last Clear was performed or the last time power was removed
Battery Voltage
Battery Voltage shows the supply voltage (in Volts).
Temperature
Internal temperature (in degrees Celsius)
RSSI Level
Received Signal Strength Indication (in dBm).
Preamble Good
The number of correctly decoded transmissions received since power up. Used with
Preamble Total, this serves as an indication of how well the unit is receiving data.
Preamble Total
The number of total transmissions detected since power up. Used with Preamble Good, this
serves as an indication of how well the unit is receiving data.