SECTION 7
um_tslm rev3.doc
Page 47 of 62
Temp
Temp displays the internal case temperature (in Celsius) of the unit transmitting the
diagnostics.
Batt
Batt displays the supply voltage (in volts) of the unit transmitting the diagnostics.
FwdP*
FwdP displays the forward power (in watts) of the unit transmitting the diagnostics.
RevP*
RevP displays the reverse (reflected) power (in watts) of the unit transmitting the
diagnostics.
*Forward and Reverse Power diagnostics are available only from T-96SR modems. These
fields are included to support TSLM infrastructure and will be blank if the remote modem is
a TSLM.
Time
Time is the time stamp when the diagnostics were received.
Short ID Filter List
The Short ID Filter list allows the user to filter Short IDs.
Display
Display allows the user to format on screen data. The following options are available:
•
Scroll (by time): displays the diagnostics as they are received
•
Slotted (by ID): sorts the diagnostics by Short ID. Using this option, each Short ID
will have one row of diagnostics, showing the most recent Short ID
Progress
The Progress panel shows the sorting progress of the diagnostics if a filter was changed.
Pause
The Pause check box allows the user to pause the reception of the diagnostics for scrolling
through the grid.
Clear
The Clear button allows the user to clear the display and current Online Diagnostics.