SECTION 7
um_tslm rev3.doc
Page 44 of 62
Network Statistics
Offline Network Statistics are only available when the ‘Online Diagnostics’ option is enabled
for the network. Online Diagnostics are located on the Setup Modem/Radio Parameters
screen. When enabled, diagnostic information is inserted at the beginning of each
transmission from each unit in the network. While the network may remain online, the
monitoring unit is in ‘Setup’ mode (flashing green LED).
Network Statistics:
Remote
The Remote drop down allows the user to select (from the list Remotes) which network
statistics to display.
ID Truncated
ID Truncated shows the user the Long and Short ID are not the same.
RSSI Level
The RSSI level shows the current RSSI level (in dBm) while the Local unit is receiving.
Temperature
Temperature shows the internal case temperature (in Celsius).
Battery Voltage
Battery Voltage shows the supply voltage (in Volts).
Forward Power
Forward Power shows forward power (in Watts). This parameter is available only when
remote modem is a T-96SR
Reverse Power
Reverse Power shows reverse power (in Watts). This parameter is available only when
remote modem is a T-96SR.
RSSI Panel
The RSSI panel shows the current RSSI level (in dBm) while the local unit is receiving.
Modem Select:
Local ID
The Local ID button allows the user to send commands to the local unit (the unit interfaced
to the computer). The Short ID for this unit is shown.