When Online Diagnostics are received and a diagnostic field falls outside the Filter Limits, the diagnostic
information is considered invalid and is not displayed.
Low/High RSSI: Low/High RSSI represent the low and high limits for the RSSI diagnostics (in dBm).
Low/High Temp: The Low/High Temp represents the low and high limits for the temperature diagnostics
(in degrees C).
Low/High Batt: Low/High Batt represents the low and high limits for the battery voltage diagnostics (in
volts).
Low/High Fwd Pwr: Low/High Fwd Pwr represents the low and high limits for the forward power
diagnostics (in watts).
Low/High Rev Pwr:
Low/High Rev Pwr represents the low and high limits for the Reverse Power diagnostics (in watts).
Open
The Open button allows the user to restore Diagnostic IDs and Alarms from a previously saved file.
Save
The Save button allows the user to save the current Diagnostic IDs and Alarms to the current file.
Save As
The Save As button allows the user to save the current Diagnostic IDs and Alarms to a name different
than
the current file.
2-21
001-4006-101
2.5.9 OFFLINE LINK TEST
The Offline Link Test is used to test the link between two units: the local unit interfaced to the computer
and
a remote unit. Blocks of data are transmitted to the remote unit and the remote unit decodes and returns
them. The transmitted and received blocks of data are compared and the ratio of the results are calculated.
NOTE: An Offline Link Test requires suspension of user network operation.
Remote Select
Local ID
The Local ID is the Long ID of the unit connected to the computer. The Short ID is displayed.
Remote ID
The Remote ID combo box allows selection of the unit (by choosing it‟s Remote ID) from which the Link
Test information is gathered. Remote IDs are set up in the Diagnostic IDs and Alarms Screen. The Short
ID
is displayed.
An Offline Link Test returns the following statistics:
Figure 2-16 Offline Link Test Screen