001-5006-000_FCC.docx
Page 12
1.3.4
SETUP and COM Ports
The SETUP and COM serial connections are DE-9F RS-232 ports.
Serial port considerations:
Guardian radio modem SETUP and COM ports are Data Communication Equipment
(DCE) devices
In general, equipment connected to the Guardian’s SETUP / COM serial port is Data
Terminal Equipment (DTE) and a straight-through cable is recommended.
Note: If a DCE device is connected to the Guardian SETUP / COM port, a null modem
cable/adapter is required.
The pin-out for the SETUP and COM ports are shown in Table 1.3.
Table 1.3 Pin-out for DCE SETUP and COM port, 9 Contact DE-9 Connector
Contact
EIA-232F Function
Signal Direction
1
DCD
(1)
DTE
←
DCE
2
RXD
DTE
←
DCE
3
TXD
DTE
→
DCE
4
DTR
DTE
→
DCE
5
GND
DTE --- DCE
6
DSR
(2)
DTE
←
DCE
7
RTS
(1)
DTE
→
DCE
8
CTS
(1)
DTE
←
DCE
9
RING
(3)
DTE
---
DCE
(1) Programmable.
(2) Always asserted
(3) For future use
The DCD, DTR, RTS and CTS control lines are programmable. Refer to section 6.4 for serial
port control line configurations.
1.3.5
Power Connector
The Guardian is supplied with a right-angle power connector (10-30 VDC). Table 1.4 shows
the pin-out of the power connector.
Table 1.4 Pin-out of the power connector
Contact #
(Left to Right)
Color
Description
4
Fan Power Output (5V)
3
Black
Ground
2
Red
Positive (10-30) VDC
1
White
Enable
Note: The White Enable line must be tied to the red positive lead of the connector for the
Guardian to function.