IT6860B User manual
用户使用手册
24
TRIG=MANU
MEM=GROUP1
TIMER=OFF
List Function (>List Set)
List mode allows you to create a sequence of steps, store it into the power supply’s non
volatile memory and execute it. The input parameters for generating a list include the time
unit (min or sec), the step voltage, step current, step time and whether continue to the next
step, repeat count and whether save the file. Each list file can be edit up to 150 steps.
Once a trigger signal is received, the programmed list will be executed once. Once finished,
the instrument will pause until the next trigger signal is received.
Operation:
Generate file:five steps:
1
)
Press
(Shift)
+
I-set
I-set
(
Menu
)
into menu operation
2
)
VFD displays
MAX VOLT,
press
to select
LIST SET
,
press
Enter
to confirm
3
)
VFD displays
LIST STATE
, press
Enter
to confirm.VFD displays
LIST>OFF
, press
to select
>LIST >ON
, press
Enter
to confirm. Then
Enter
button will be lit. You
have enables list mode.
4
)
Press
to select
LIST EDIT
, press
Enter
to confirm.
5
)
VFD displays
TIME SEC
, press
Enter
to confirm. Continue to next step, or press
to select
>TIME MIN
. Press
Enter
to confirm. Note: no matter you select SEC or
MIN,the adjustable range is 0.1~9999.9
6
)
VFD displays
VSET 0.000
, press numeric keys
0
to
9
or adjust rotary knob to set
voltage, press
Enter
to confirm.
7
)
VFD displays
ISET 0.0000
, press numeric keys
0
to
9
or adjust rotary knob to set
current, press
Enter
to confirm.
8
)
VFD displays
SEC 0.1
, press numeric keys
0
to
9
or adjust rotary knobs to set
time press
Enter
to confirm.
9
)
VFD displays
NEXT >YES
, press
Enter
to confirm.
10
)
Repeat steps from 5
)
~8) for four times. The last time, when VFD shows
NEXT >YES
,
press
to select
NEXT >NO
, press
Enter
to confirm.
11
)
VFD displays
REPET 1
, press numeric keys
0
to
9
or adjust rotary knob to set
cycle counts, press
Enter
to confirm.
Repeat count range:1~65535.
12
)
VFD displays
SAVE >NO
, press
Enter
to confirm.
In this condition, the current list file does not be saved. It can only run once. As long as
you quit the list mode or turn off the unit, the list file will not exist anymore.
You also can press
to select
>SAVE FILE0
to save the file into assigned memory
location for quick recall. Press
Enter
to confirm.
There are four memory areas to save a list file (FILE0~FILE3).
13
)
If you intends not save the list file, VFD will directly display
LIST EDIT
.