IT6860B User manual
用户使用手册
21
(SEC)
MIN
Select minute as time unit
VSET
Set step voltage
ISET
Set step current
SEC
Set step delay time(0.1-9999)
NEXT
(YES)
YES
Continue to edit the next step
NO
finish list file edit
REPET 1-65535
Set repeat count
SAVE
NO
Do not save the current list file. In this
mode, the file can only run for one time.
Once you quit the list mode or turn off
the unit, the file cannot be recalled.
FILE0-FILE3
save list file to assigned memory
location
EXIT
Quit list menu
POWER
INFO
MODEL
Model information
VER
Firmware version
SN-1
First six number of SN
SN-2
Middle six number of SN
SN-3
Last six number of SN
EXIT
Quit information menu
EXIT
MENU
Quit menu
Note: Press
Esc
button can help to quit Menu setup and any function button
operation.
2.
Menu Function
Maximum voltage
(
>MAX VOLT
)
The maximum voltage can be adjusted from 0A to maximum rated voltage of each model.
To set max volt:
(1) Press
(Shift) +
I-set
I-set
(Menu) button to enter menu setup, scroll to >MAX VOLT item
and press
Enter
to confirm.
(2) Using
button to adjust cursor position and set max voltage.
Output voltage set will be limited within the range of max voltage.
MAX VOLT default set is the rated voltage of each model.