Data Logging
Date, time, speed and torque can be logged during operation to a memory stick. The data logging interval defaults to one
second, and can be set from 1-999 seconds.
Insert memory stick or computer USB cable to initiate data logging. USB icon is visible on the Dashboard. When using a
memory stick, utilize the mixer keypad for operation. The mixer creates a new set of data logging files when powered off
and on, or when the memory stick is removed and replaced.
Set Data Logging Intervals
A memory stick or computer connection must be detected to initiate data logging. Set the data logging interval between 1
and 999 seconds.
From the Settings Menu Screen:
1. Press DATA LOGGING INTERVALS button to open the Keypad Screen.
2. Enter total number of seconds (1-999)
When in operation, the mixer will create the following two files on the memory stick:
Status file labeled Date_Serial# defining mixer settings.
Serial Number
15401234
Date of Manufacture
2015-10-01
Hours of Operation
HH:MM:SS
Software Version
X.X.X
Speed Setting
100
Maximum Torque
2500
Minimum Torque
0
Resume on Power UP
NO
Timer Continue on Alarm
NO
Torque Continue on Alarm
NO
Data Logging Interval
2
Data logging file labeled Serial#_MixerName with data.
Date
Time
Speed (RPM) Torque (Ncm)
2016-02-03
14:34:18
0
0
2016-02-03
14:34:20
25
243
2016-02-03
14:34:22
47
290
2016-02-03
14:34:24
73
318
2016-02-03
14:34:26
79
332
2016-02-03
14:34:28
90
346
2016-02-03
14:34:30
97
354
2016-02-03
14:34:32
98
356
Data format: YYYY-MM-DD,HH:MM:SS,RPM,Ncm