ENCORE GROUND Rev. 1 2021-10
www.cafection.com 800-561-6162
64
SERVICE & INSTALLATION MANUAL for Cafection's Encore Ground
7.8.2 Brew Group
Brew Chamber and Funnel
Frequency: weekly or every 200 cycles
1. Place a large cup or container under the dispensing
nozzle to collect the hot rinse water.
2. Perform several rinse cycles (see section 7.1).
3. Remove the brown tube from its support. Remove
the brew chamber's funnel to dislodge coffee residue
trapped underneath it and rinse it under hot water.
4. Reinstall the funnel and the tube in its support. Make
sure the tube is against the wall of the funnel. Water
must form a circular motion when being dispensed.
5. Order a large coffee to ensure that the brew
chamber is working properly.
Warning! Place a container large enough (size
specified on the screen). Water is VERY HOT.
Crush hazard. Handle the brew group cautiously.
Brew Group Assembly
Frequency: monthly or every 1,000 cycles
In order to maintain optimal performance of the brew group
assembly, it is recommended to remove it from the unit,
clean it and rinse it under hot water.
1. Open the brewer's door and remove the front panel.
2. Cut the filter paper with scissors on both sides of the
brew chamber.
3. Flip up the retaining rod, push the locking pin to the
right, then down to release the brew group and pull it
outward.
4. Rinse the brew group thoroughly under hot water to
remove visible soil.
5. Remove the funnel from the brew chamber and rinse it
thoroughly under hot water.
6. Air dry completely before reinstalling the parts.
7. Order a large coffee to ensure that the brew group is
working properly.
The brew group assembly can also be cleaned using urn
cleaner. See section 7.2 for cleaning instructions.
Brew
chamber
Brew chamber
funnel
Brew chamber
tube retainer
C
le
an
in
g
an
d
San
it
iz
in
g