ENCORE GROUND Rev. 1 2021-10
www.cafection.com 800-561-6162
40
SERVICE & INSTALLATION MANUAL for Cafection's Encore Ground
6.5.3 Brew Cycles Settings Sub Tab
1. This table is used to set the brew cycles.
Press on a value to modify it and enter
the desired number of units using the
numeric keyboard.
2. This button is used to bring all brew
cycles values back to factory settings.
3. These buttons are used to discard or
save any current modification.
The Encore Ground has four (4) different brew cycles. The brew cycle is automatically
selected in accordance with the water quantity in the coffee-based recipe.
Cycle #1 (101 to 187 water units)
Standard brew cycle.
Cycle #2 (188 to 269 water units)
Three (3) stirring cycles during which the total quantity of water is dispensed in three (3)
shots. The mix is stirred three (3) times, ensuring that the coffee completely comes into
contact with water. Ideal for recipes with high water and coffee volumes.
Cycle #3 (270 water units and more)
Double brew cycle. The machine splits the water and ingredients quantities in half to
perform two (2) separate brew cycles.
Cycle #4 (100 water units or less)
Quick brew cycle. Ideal for recipes with low water level.
Adjustable Settings
Pause 1
First contact time between water and coffee grounds. To get more extraction, increase this
value.
20 units = 1 second.
Pause 2
Second contact time between water and coffee grounds. To get more extraction, increase
this value.
20 units = 1 second.
Move 3
Position where the piston stops before dispensing the coffee into the cup.
A setting too high will prematurely open the brew chamber, causing a mess of wet
coffee grounds inside the machine.
A setting too low will not pull all coffee through the filter.
This setting must be changed with care.
Pause 3
Pause time before the brew chamber opens. If there are wet coffee grounds on the filter paper
at the end of the cycle, increasing this setting might solve the issue.
20 units = 1 second.
S
e
r
v
ic
e Mo
d
e
1
3
2