Document type:
Title:
Revision date:
Revision:
Installation Guide (MUT)
Mod. SY1527, universal multichannel power supply system
03/12/02
3
NPO:
Filename:
Number of pages:
Page:
00103/97:1527x.MUTx/03 HWGUIDE_REV3.DOC
62
25
WARNING: The primary power supply can be inserted or extracted from the
appropriate housing only if the system is turned off and unplugged from the
mains.
CAUTION
DO NOT COVER THE COOLING GRID!
Table 3.1 – Mechanical and Electrical features of the A1531 Primary Power Supply
Mechanical features
-
20TE-wide, 4U-high mechanics;
-
Depth: 250 mm;
-
Equipped with sliding guides.
Input features
-
Monophase input from 100 Veff to 230 Veff,
50-60 Hz with Power Factor Correction (PFC);
-
Input current limitation at Power-ON less than
15 A (230 Veff input);
- Soft
start;
-
Hold up time
≥
20 ms.
Output features
-
Output voltage: +12 V, 8 A;
-12 V, 8 A;
+5 V, 20 A.
3.4.3
Power Supply Units (Mod. A1532)
The Power Supply Units (Model A1532) deliver voltage (+48 V, 750 W) for the system
boards supply. The SY1527 mainframe can house up to three A1532 units allowing to
reach a 2250 W maximum output power.
Any configuration of the SY1527 system includes at least one A1532 unit for the power
supply of the board section.
Each of the A1532 Power Supply Units can be placed in any of the housings from #1 to
#3 on the mainframe’s front part , i.e. any housing except for the first housing on the right
(Housing #0) which is reserved to the Primary Power Supply (refer to Fig. 3.1, p.19).
Both the Primary Power Supply and the Power Supply Units have bias pins to be
inserted into the relevant mating holes of the backplane. In order to avoid a
misplacement of the Primary Power Supply, the latter has a bias pin placed in a different