![Caen ELS FAST-PS-M Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/caen-els/fast-ps-m/fast-ps-m_user-manual_3293989037.webp)
FAST-PS-M – User’s Manual
37
Config Page
The
Config Page
is reachable by selecting the corresponding rectangle from the
Menu Page
.
This page allows the user to set the control mode of the power supply – e.g.
LOCAL or REMOTE – to select the regulation mode (C.C. or C.V.) and to set the slew
rate in [A/s] or [V/s] depending on the selected regulation mode.
An example of a
Config Page
visualization is shown in
Figure 21
:
Figure 21: Config Page
The firmware installed version is shown at the bottom of this page (FW
Version).
Advanced Page
The
Advanced Page
is reachable by selecting the corresponding rectangle from
the
Menu Page
.
This page allows to locally set the power supply Ethernet IP address, the Network
Mas and the Gateway.
An example of an
Advanced Page
visualization is shown in
Figure 22
:
Figure 22: Advanced Page
It is very important to notice that once the "OK" button has been clicked,
the user can remotely communicate and get control of the power supply again only
by opening a new TCP socket to the IP that has just been set.