Step 12
Connect your source to the traveller’s inlet pipe. Verify that the mainline connection and
A )
inlet pipe connection are secure.
Failing to verify secure connections will lead to pooling of water. This will
muddy the area around the traveller and may cause injury to operators
and/or spectators
Verify that all operators and/or spectators are free and clear of the areas around the
B )
traveller and sprinkler cart. Slowly bring everything up to a pressure of 50 psi (345 kPa)
to purge air from all hoses and the traveller. Once air has been completely purged from
all hoses and the traveller, slowly raise the pressure up to a maximum of 150 psi (1,034
kPa).
Failing to remain free and clear of the areas around the traveller and
sprinkler cart may result contact with the sprinkler discharge. In addition,
any connection that has not been secured may break free.
Coming into contact with the high pressure water stream and/or any
hardware from a broken connection will result in serious injury and/or
death to operators and/or spectators. It may also damage the traveller.
An inlet pipe pressure range of 120 psi (827 kPa) to 150 psi (1,034 kPa) will result in a
pressure range of 50 psi (345 kPa) to 110 psi (758 kPa) at the sprinkler. This will result in
even, uniform irrigation pulls if you have selected an appropriate nozzle setup that receives an
appropriate flow volume.