background image

new RIVER IDRO T2 - TESIS Airtight T2 - MIRA T2 - MAYA idroT2

9

LEGENDA 

WHERE TO DISPOSE

MATERIALS

A. OUTER CLADDING

If there is any, to be disposed of separately based on 

the material used:

Metal                                   

Glass                                       

Tiles or ceramics  

Stone                                     

B. GLASS DOORS

If there is any, to be disposed of separately based on 

the material used:

Glass ceramic (fire door): to be disposed of with 

inert or mixed waste

Tempered glass (oven door): to be disposed of with 

glass 

C. INTERIOR CLADDING

If there is any, to be disposed of separately based on 

the material used:

Metal

Refractory materials      

Insulating panels

Vermiculite 

Insulation, vermiculite and refractory materials 

that have come into contact with flames or exhaust 

gases (dispose of in mixed waste)

D. ELECTRIC AND ELECTRO-

NIC COMPONENTS

To be disposed of separately in authorised centres, 

as indicated in the WEEE directive 2012/19/EU and 

the relative national transposition.

Wiring, motors, fans, circulators, display panels, 

sensors ignition plug, electronic cards, batteries.

E. METAL STRUCTURE

To be disposed of separately with metal                      -

F. COMPONENTS THAT CAN-

NOT BE RECYCLED

To be disposed of with mixed waste                

E.G.: Gaskets, rube piping, silicone or fibres, plastic.

G. HYDRAULIC COMPONENTS

Piping, fittings, expansion vessel, valves. If there 

are any, to be disposed of separately based on the 

material they are made of:

Copper

Brass

Stainless steel

Other materials

6.2 

INFORMATION FOR MANAGEMENT OF ELECTRIC AND ELECTRONIC APPLIANCE WASTE CON-

TAINING BATTERIES OR ACCUMULATORS

Fig. 2 - Waste disposal

This symbol, which is used on the product, batteries, accumulators or on the packaging or documents, means that at the end of its 

useful life, this product, the batteries and the accumulators included must not be collected, recycled or disposed of together with 

domestic waste.

Improper management of electric or electronic waste or batteries or accumulators can lead to the leakage of hazardous substances 

contained in the product. For the purpose of preventing damage to health or the environment, users are kindly asked to separate 

this equipment and/or batteries or accumulators included from other types of waste and to arrange for disposal by the municipal 

waste service It is possible to ask your local dealer to collect the waste electric or electronic appliance under the conditions and 

following the methods provided by national laws transposing the Directive 2012/19/EU.

Separate waste collection and recycling of unused electric and electronic equipment, batteries and accumulators helps to save 

natural resources and to guarantee that this waste is processed in a manner that is safe for health and the environment.

For more information about how to collect electric and electronic equipment and appliances, batteries and accumulators, please 

contact your local Council or Public Authority competent to issue the relevant permits.

6.3 

INSTRUCTIONS FOR PACKAGING DISPOSAL

The material that the appliance’s packaging is made of must be managed correctly, in order to make collection, reuse, recovery 

and recycling easier, where possible.

The table below illustrates the possible components that the packaging is made of, and the relative instructions for correct disposal.

Содержание TESIS 16 AIRTIGHT T2

Страница 1: ...EN USER MANUAL PELLETTHERMOSTOVE OriginalInstructions 2022CADELsrl Allrightsreserved Tuttiidirittiriservati new RIVERIDRO 16T2 23T2 23H2 OT2 MIRA 16T2 22T2 TESIS 16 23 AIRTIGHTT2 MAYA IDRO 16T2 24T2...

Страница 2: ...18 CHIMNEY SWEEP FUNCTION FOR MAINTENANCE TECHNICIANS ONLY SEE SECTION N 21 9 FUEL 21 9 1 FUEL 21 9 2 PELLET SUPPLY 22 10 SAFETY DEVICES AND ALARMS 22 10 1 PRESSURE SWITCH 22 10 2 SMOKETEMPERATURE PR...

Страница 3: ...nual is lost you can request another copy from the localTechnical Dept or download it directly from the company s website Alllocalregulations includingthosereferringtonationalandEuropeanstandards must...

Страница 4: ...reducing the interval between routine maintenance operations according to the operating condition of the product We furthermore point out that these operating conditions increase the risk of premature...

Страница 5: ...d with 1 meter If the floor is made of combustible material we recommend using a protector made of in combustiblematerial steel glass etc thatalsoprotectsthefrontpartfromanyfallingburnt particles duri...

Страница 6: ...urer Whentheproductisswitchedonforthefirsttime itisnormalforittoemitsmokeduetothepaintheatingupforthefirsttime Therefore make sure the room it is installed in is well ventilated Periodically check and...

Страница 7: ...nt of a fault the customer must have the guarantee certificate and present it with the proof of purchase document to theTechnical Assistance Office Theguaranteedoesnotcovermalfunctionsand ordamagetoth...

Страница 8: ...stance Services 6 DISPOSAL OF MATERIALS 6 1 WARNINGS FOR THE CORRECT DISPOSAL OF THE PRODUCT The owner is the sole party responsible for demolishing and disposing of the product This must be performed...

Страница 9: ...ACCUMULATORS Fig 2 Wastedisposal Thissymbol whichisusedontheproduct batteries accumulatorsoronthepackagingordocuments meansthatattheendofits useful life this product the batteries and the accumulators...

Страница 10: ...ES BUBBLEWRAP PROTECTIVE SHEET LABELS POLYETHYLENE LD PE 04 SORTED waste collection PLASTIC Check the instructions of the com petent body POLYSTYRENE FOAM PEANUTS POLYSTYRENE PS 6 SORTED waste collect...

Страница 11: ...djust the inner springing stress After 2 hours the smell of paint and smoke will disappear By using the stove the varnish inside the combustion chamber could be subjected to alterations This occurrenc...

Страница 12: ...ate Timer Sleep only with the stove on Settings Info Date and time setting To set the date and time act as follows Press the menu button Select Time and Date Select by pressing menu Scroll with the ar...

Страница 13: ...ect On with the keys Press menu to confirm and esc to exit c Feed screw loading Allows to fill the pellets loading system It can only be activated with the boiler switched off it displays an 180 count...

Страница 14: ...utdown t function act as follows Press the menu button Scroll to Settings using the arrows Press menu to confirm Scroll to Eco shutdown t using the arrows Press menu to confirm Enter the minutes with...

Страница 15: ...f 1 minute during which the panel displays the countdown seconds Pump it is activated for a fixed time of 10 seconds during which the panel displays the countdown 3 way the 3 way valve is activated fo...

Страница 16: ...u to confirm and esc to exit q Technical menu To access the technical menu one must contact an assistance centre as one needs a password to enter To intervene on the technical menu act as follows Pres...

Страница 17: ...or the glass tends to blackens and the burningpottobecomeencrusted cleanthestove cleanthefumeconduitandthechimneyflue ATTENTION Makesurepelletsandashhavenotaccumulatedinthebrazierduetofailedignition...

Страница 18: ...scroll toTIMER with the arrows press the Menu key the system proposes P1 Press the keys for the subsequent timers P2 P3 P4 P5 P6 to activate P1 press the Menu key press and select ON confirm with the...

Страница 19: ...all devices present are satisfied the ECO shutdown t time decrease starts by default 10 minutes it can be changed within the Settings menu During this stage the panel displays ON with a small flame a...

Страница 20: ...eposits forming at the bottom of the brazier itself caused by poor quality fuel or fuel that produces a lot of ashes The values available are from 27 to 27 with variations of 3 points at a time The va...

Страница 21: ...oduct liability 9 2 PELLET SUPPLY Fig 13 Wrongopeningofthepelletsbag Fig 14 Rightopeningofthepelletsbag It is necessary to avoid to fill the hopper with the pellet when the stove is running Do not get...

Страница 22: ...wer cut that lasts over 10 with the boiler on or in the start up stage when the boiler is powered again it goes back to the previous operating condition with the following procedure 1 It performs a co...

Страница 23: ...ermostat alarms The temperature of the pellets hopper or the water temperature exceed the envisioned safety threshold Wait for the cooling stage to end cancel the alarm and restart the boiler setting...

Страница 24: ...e After a long ineffective time before turning on the stove check if there are obstructions in the fume exhaust If the stove had been using continuously and intensely the whole system chimney included...

Страница 25: ...er we recommend removing part C near the brazier and using a vacuum cleaner nozzle to remove any ash build up Fig 18 Drawerremoval Fig 19 Brazierremoval 11 5 ASH DRAWER CLEANING MAYA Lift part C from...

Страница 26: ...utorizedtechnicianin order to guarantee the good running of the stove Useexclusivelyoriginalspareparts 11 11 GLASS CLEANING The glass ceramic of the fire door is able to stand till 700 C but not to th...

Страница 27: ...falls into the lower area around the brazier Use a vacuum cleaner to remove all the fallen material Fig 23 Pipeunitcleaning 11 14 SHUTDOWN END OF SEASON At the end of each season before switching the...

Страница 28: ...an check the inner electri cal mechanicalcomponents PARTS FREQUENCY 2 3 DAYS 7 DAYS 1YEAR UNDERTHE USER S RESPONSIBILITY Brazier Ash pan Glass Lower compartment Turbulators BYTHE QUALIFIEDTECHNICIAN C...

Страница 29: ...connected Burned protection fuse in the electric socket Replace the protection fuses in the electric socket 3 15A 250V Faulty control display Replace the control display Faulty flat cable Replace the...

Страница 30: ...the stove burning pot obstructed holes with too ash remains Have the fan blades and auger cleaned see SMOKE RPMVARIATION User Manual Obstructed exhaust The exhaust chimney is partially or totally obs...

Страница 31: ...block the system When this flashing message appears upon start up it means that the preset operating hours have elapsed before maintenance Contact the service centre 12 2 PROBLEM SOLVING THERMOSTOVE P...

Страница 32: ...OSURE of the PIPE FITTINGS Radiators cold in the winter Room thermostat local or remote adjusted too low If remote thermostat check whether it is defective Adjust it to a higher temperature Replace it...

Страница 33: ...O2 150 mg Nm3 NOx al 13 O2 94 mg Nm3 Heat output Nominal heat output Pnom 16 kW Minimum heat output indicative Pmin 4 9 kW Useful efficiency NCV as received Useful efficiency at nominal heat output t...

Страница 34: ...l 13 O2 150 mg Nm3 NOx al 13 O2 94 mg Nm3 Heat output Nominal heat output Pnom 22 4 kW Minimum heat output indicative Pmin 4 9 kW Useful efficiency NCV as received Useful efficiency at nominal heat ou...

Страница 35: ...2 94 mg Nm3 Heat output Nominal heat output Pnom 22 4 kW Minimum heat output indicative Pmin 4 9 kW Useful efficiency NCV as received Useful efficiency at nominal heat output th nom 92 Useful efficien...

Страница 36: ...CADEL srl 31025 S Lucia di Piave TV Via Foresto sud 7 Italy Tel 39 0438 738669 Fax 39 0438 73343 www cadelsrl com www free point it www pegasoheating com Rev 00 2022...