31
SHELL UP - SHELL PS -BREEZE AIRTIGHT
PROBLEM
CAUSE
SOLUTION
INTERVENTION
The exchanger fan
continues to turn
even though the
stove has just cooled
Faulty fume tempe-
rature probe
Replace the fume probe.
Faulty mother board Replace the mother board.
Ash remains along
the stove
Faulty or out of order
door gaskets
Replace the gaskets.
Not sealed fume
pipes
Contact an expert stove-repairer who will immediately provide for
sealing the junctions with high-temperature silicone and/or for
replacing pipes with those in compliance to current regulations. A
not sealed fume channelisation can be noxious to health.
The stove is at its
highest power but
does not heat up.
Ambient temperatu-
re reached.
The stove is at its minimum value. Increase the desired ambient
temperature.
Stove running and
display showing
"Smoke Overtepe-
rature"
Reached fume outlet
limit temperature
The stove runs at minimum. NO PROBLEM!
The stove's smoke
duct produces
condensation
Low smoke tempe-
rature
Check that the flue is not clogged.
Increase stove power to minimum (pellet drop and fan revs).
Install condensation collection cup.
Stove running and
display showing
"SERVICE"
Routine maintenan-
ce alert (it does not
block the system)
When this flashing message appears upon start-up, it means that
the preset operating hours have elapsed before maintenance.
Contact the service centre.