15 TECHNICAL DOCUMENTATION FOR LOCAL SPACE HEATERS ACCORDING TO COM-
MISSION REGULATIONS (EU) 2015/1185 - (EU) 2015/1186 (PRODUCT FICHE)
Manufacturer
CADEL srl - Via Foresto Sud 7 - 31025 Santa Lucia di Piave (TV) - Italy
Trademak: model identifier
CADEL: KRISS3 - 9kW - SHELL3 UP - SHELL3 PS
FREEPOINT: BREEZE AIRTIGHT
Description
Pellet stove
Indirect heating functionality
No
Direct heat output
9,1 kW
Indirect heat output
- kW
CPR harmonised standard
EN 14785
Notified body
KIWA S.p.a.N.0476
Preferred fuel (unique)
Compressed wood with moisture content < 12 %
YES
Wood logs with moisture content ≤ 25 %
NO
Other woody biomass
NO
η
s
85
%
EEI
125
-
Energy Efficiency Class (A++ to G scale)
A+
Space heating emissions at nominal heat output
PM (al 13% O
2
)
12,1
mg/Nm
3
OGC (al 13% O
2
)
2,1
mg/Nm
3
CO (al 13% O
2
)
63
mg/Nm
3
NO
x
(al 13% O
2
)
139
mg/Nm
3
Space heating emissions at minimum heat output
Only required if correction factors F(2) or F(3) are applied
PM (al 13% O
2
)
19,3
mg/Nm
3
OGC (al 13% O
2
)
3,9
mg/Nm
3
CO (al 13% O
2
)
274
mg/Nm
3
NO
x
(al 13% O
2
)
104
mg/Nm
3
Heat output
Nominal heat output (P
nom
)
9,1
kW
Minimum heat output (indicative) (P
min
)
2,4
kW
Useful efficiency (NCV as received)
Useful efficiency at nominal heat output (η
th,nom
)
88,7
%
Useful efficiency at minimum heat output (indicative)
(η
th,min
)
92,9
%
Auxiliary electricity consumption
At nominal heat output (el
max
)
0,077
kW
At minimum heat output (el
min
)
0,012
kW
In standby mode (el
sb
)
0,002
kW
Type of heat output/room temperature control (select
one)
Single stage heat output, no room temperature control
NO
Two or more manual stages, no room temperature
control
NO
With mechanic thermostat room temperature control
NO
With electronic room temperature control
NO
With electronic room temperature control plus day
timer
NO
With electronic room temperature control plus week
timer
YES
Other control options (multiple selections possible)
Room temperature control, with presence detection
NO
Room temperature control, with open window detec-
tion
NO
With distance control option
NO
Permanent pilot flame power requirement
Pilot flame power requirement (if applicable) (P
pilot
)
N.A.
kW
Observe the specific precautions for installation, assembly and maintenance indicated in the manual accompanying the
product.
Issue date: 30.11.2021