13.9  GASKET REPLACEMENT

In case of deterioration of fire door, hopper or fume chamber gaskets, it is necessary  to replace them by an autorized technician in 

order to guarantee the good running of the stove.

Use exclusively original spare parts.

13.10  GLASS CLEANING

The glass-ceramic of the fire door is able to stand till 700°C but not to thermal shocks.

The probable cleaning with usual sale product for glass cleaning must be effected at cool glass in order to avoid explosions.

You should clean the fire door glass every day!

13.11  SHUTDOWN (END OF SEASON)

At the end of each season, before switching the product off, it is recommended to remove all the pellets from the hopper with a 

vacuum cleaner with a long pipe.

We recommend removing the unused pellets from the hopper because they can retain moisture. Disconnect any combustion air 

ducting that can lead to moisture inside the combustion chamber but, above all, ask the specialised technician to refresh the paint 

inside the combustion chamber with the special silicone spray paints (available at any store or Technical Assistance Centre) during 

the necessary annual end of season scheduled maintenance operations. This way the paint will protect the inner parts of the com-

bustion chamber, blocking any type of oxidative process.

Fig. 35 - Shutter with fuses to remove

When not in use the appliance must be disconnected from the mains power supply. It is recommended to remove 

the power cable for additional safety, especially in the presence of children.

The service fuse may have to be replaced if the control panel display does not switch on.

There is a fusebox on the back of the product, near the power socket. 

After removing the plugs from the power socket, open the fusebox cover with a screwdriver and replace the fuses if necessary (3.15 

A delayed) - seek assistance from an authorised and qualified technician.

13.12  CHECKING THE INNER COMPONENTS

ATTENTION!

The internal electromechanical components must only be checked by qualified personnel 

whose technical expertise includes combustion and electricity.

We recommend for this yearly maintenance to be carried out (with a scheduled service contract). This operation consists of a visual 

and functional inspection of the internal components. A summary of the checks and/or maintenance operations that are essential 

for the correct operation of the product is provided below.

Содержание SHELL3 UP

Страница 1: ...EN USER MANUAL Pellet Stove 2022CADELsrl Allrightsreserved Tuttiidirittiriservati new SHELL3 UP SHELL3 PS BREEZE AIRTIGHT...

Страница 2: ...U 19 8 16 EASYSETFEATURE SEESECTIONXSETTINGSMENU A PAG 13 20 8 17 PELLETS RECIPE SEE SECTION H SETTINGS MENU A PAG 13 21 8 18 SMOKE RPM VARIATION SEE SECTION I SETTINGS MENU A PAG 13 21 8 19 CHIMNEY S...

Страница 3: ...nload it directly from the company s website Alllocalregulations includingthosereferringtonationalandEuropeanstandards mustbeobservedwheninstallingtheappliance In Italy for the installation of systems...

Страница 4: ...operating condition of the product We furthermore point out that these operating conditions increase the risk of premature wear of the product especially those parts exposed to the direct heat of the...

Страница 5: ...meter If the floor is made of combustible material we recommend using a protector made of in combustiblematerial steel glass etc thatalsoprotectsthefrontpartfromanyfallingburnt particles during cleani...

Страница 6: ...theproductisswitchedonforthefirsttime itisnormalforittoemitsmokeduetothepaintheatingupforthefirsttime Therefore make sure the room it is installed in is well ventilated Periodically check and empty th...

Страница 7: ...ault the customer must have the guarantee certificate and present it with the proof of purchase document to theTechnical Assistance Office Theguaranteedoesnotcovermalfunctionsand ordamagetotheapplianc...

Страница 8: ...rvices 6 DISPOSAL OF MATERIALS 6 1 WARNINGS FOR THE CORRECT DISPOSAL OF THE PRODUCT The owner is the sole party responsible for demolishing and disposing of the product This must be performed in compl...

Страница 9: ...e of Copper Brass Stainless steel Other materials 6 2 INFORMATION FOR MANAGEMENT OF ELECTRIC AND ELECTRONIC APPLIANCE WASTE CON TAINING BATTERIES OR ACCUMULATORS Fig 2 Wastedisposal Thissymbol whichis...

Страница 10: ...ARDBOARD SHEET CORRUGATED CARDBOARD PAP 20 SORTED waste collection PAPER Check the instructions of the com petent body APPLIANCE BAG BAG OF ACCESSORIES BUBBLEWRAP PROTECTIVE SHEET LABELS POLYETHYLENE...

Страница 11: ...asoheating com it documenti 7 2 NAVEL STAND ALONE OPTIONAL Procedureifonlyvalidformodelswith NAVELSTANDALONEWi Fitechnology ATTENTION InstallationmustONLYbecarriedoutbyspecialisedpersonnel The manufac...

Страница 12: ...ours the smell of paint and smoke will disappear By using the stove the varnish inside the combustion chamber could be subjected to alterations This occurrence can be attri butedtodifferentreasons ane...

Страница 13: ...te Timer Sleep only with the stove on Settings Info Date and time setting To set the date and time act as follows Press the menu button Select Time and Date Select by pressing menu Scroll with the arr...

Страница 14: ...with the keys Press menu to confirm and esc to exit c Screw Loading To select Screw loading only when the boiler is switched off act as follows Press the menu button Scroll to Settings using the arro...

Страница 15: ...dify the with the keys Press menu to confirm and esc to exit i Smoke Fan rpm To change the parameter act as follows Press the menu button Scroll to Settings using the arrows Press menu to confirm Scro...

Страница 16: ...at output the ambient temperature and the big flame see Fig 11 If the ambient temperature value exceeds the limit set on the button panel in the temperature set the heat output is brought toitslowestv...

Страница 17: ...or Fire Press menu to access the selected option Modify with the keys Press menu to confirm and esc to exit Set Room T this function allows setting the desired temperature in the room where the stove...

Страница 18: ...operoperationofthetimer There are sixTIMER programmes for each one the user can decide the start up and shutdown time as well as the day of the week in which it is active Whenoneormoreprogrammesareact...

Страница 19: ...vate the Auto Eco mode and adjust the time refer SETTINGS MENU a pag 13 Thepossibilitytoadjustthe tOffTimeEco comesfromtheneedtoensureproperoperationinthevariousroomstheboilercan be installed in and p...

Страница 20: ...arameters The Easy Set feature makes it possible to adjust combustion more easily in the event that one should notice that the stove does not properly burn the fuel In the Settings menu under the head...

Страница 21: ...horisedtechnician ActivatesonlywiththeEasySetfunctiondisabled SET 0 If the installation presents difficulties for smoke evacuation no draught or no pressure in the duct the smoke and ash expulsion spe...

Страница 22: ...he weight Percentage of ash max 1 2 of the weight A1 less than 0 7 Diameter 6 1 8 1 mm Length 3 40 mm Content 100 untreated wood without the addition of binding agents The company recommends using cer...

Страница 23: ...endowed with a ventilation system The air blown from fans keeps the appliance at a low temperature range in order to avoid high stresses to the materials which make it up Do not cover the hot air out...

Страница 24: ...bling start up or stopping the product when the temperature drops below the preset value 12 3 CONTACT THERMOSTAT IN THE FUEL HOPPER If the temperature exceeds the preset safety level it immediately sh...

Страница 25: ...ed Clogged flue Damaged ignition resistance A02 The fire goes off abnormally Check the level of pellets in the hopper A03Thermostat alarms The temperature of the pellets hopper or the water temperatur...

Страница 26: ...ely the whole system chimney included must be cleaned and checked more frequently In case of replacement of damaged pieces please ask for the original spare part at the Autorized Retailer 13 2 BEFORE...

Страница 27: ...and will release a written declaration of the safety of the appliance This operation must be executed at least once a year 13 6 GENERAL CLEANING For cleaning external and inner parts of the stove do...

Страница 28: ...orTechnicalAssistanceCentre during thenecessaryannualendofseasonscheduledmaintenanceoperations Thiswaythepaintwillprotecttheinnerpartsofthecom bustion chamber blocking any type of oxidative process Fi...

Страница 29: ...SOLVING Before of every Authorized Technician intervention the same Technician has the duty to check if the parame tersofthemotherboardcorrespondtothoseofthetableyouown Incaseofdoubtsregardingtheuseo...

Страница 30: ...loading Check if on the display there is an ACTIVE ALARM Have the stove checked Flames are weak and orange coloured pellets do not burn properly and the glass blackens Not sufficient com bustion air...

Страница 31: ...lisation can be noxious to health The stove is at its highest power but does not heat up Ambient temperatu re reached The stove is at its minimum value Increase the desired ambient temperature Stove r...

Страница 32: ...104 mg Nm3 Heat output Nominal heat output Pnom 9 1 kW Minimum heat output indicative Pmin 2 4 kW Useful efficiency NCV as received Useful efficiency at nominal heat output th nom 88 7 Useful efficie...

Страница 33: ...CADEL srl 31025 S Lucia di Piave TV Via Foresto sud 7 Italy Tel 39 0438 738669 Fax 39 0438 73343 www cadelsrl com www free point it www pegasoheating com Rev 00 2022...

Отзывы: