7.4
FUME PASSAGE CLEANING
Every end-of-season (or every 2000 hours of operation) it is necessary to clean the fume passages.
• Remove the door (see the dedicated chapter).
• Undo the hex head screws that block the cast-iron tiles of the hearth, on both sides (see
Fig. 84
).
• Push the head of the firebox up (see
Fig. 85
), tilt the piece and pull it out (see
Fig. 86
).
Fig. 84 - Remove the hex screws
Fig. 85 - Remove the head of the firebox 1
Fig. 86 - Remove the head of the firebox 2
• Then remove the side walls of the firebox (see
Fig. 87
).
• Lastly remove the back panel of the firebox (see
Fig. 88
).
Fig. 87 - Remove the back panel of the firebox
Fig. 88 - Remove the side walls
• Clean with a pipe cleaner and suction any ash accumulated inside (see
Fig. 89
).
• Part of the ash will fall into the compartment below the firebox (see
Fig. 90
). See the previous chapter for the cleaning ope-
ration.
Fig. 89 - Clean with pipe cleaner
Fig. 90 - Vacuum out the ash