KOBE - FENICE - SPARK - INDACO - PRINCE - GO - ECLIPSE
24
6.18.1 Ducting solutions:
SOLUTION A
: ducting with the rear hot air outlet
Fig. 63 - Diverter removal
Fig. 64 - Insert pipe
• Remove the air diverter (see
Fig. 63
).
• The stove is ready to be ducted, position the pipe as shown in the photo (see
Fig. 64
).
SOLUTION B
: ducting with the upper hot air outlet.
Top ducting requires 1 kit code 5020003 (optional).
Fig. 65 - Diverter removal
Fig. 66 - Remove the cap
Fig. 67 - Connect the flexible hose
• Remove the left side panel (see dedicated chapter).
• Remove the air diverter (see
Fig. 65
).
• Remove the upper cap where the ducting will come out (see
Fig. 66
).
• Connect the flexible hose to the duct fan (see
Fig. 67
).