DATA
P1
P2
P3
P4
P5
Stove depression -
temperature 11 kW 25 Pa - 120°C
44 Pa - 138°C
57 Pa - 165°C
64 Pa - 185°C
70 Pa - 200°C
NB: for good combustion, the depression values must be between ± 5 Pa and the temperature values between ± 10°C.
7
SPECIAL MAINTENANCE
7.1
INTRODUCTION
For a long working life of the stove, have a periodic cleaning of the stove as described in the following paragrafs.
• Fume outlet pipes (fume c chimney flue + chimney pot) must always be cleaned, scrubbed and checked by an autho-
rized technician in compliance with local regulations, with the instructions of the manufacturer and those of your insurance
company.
• If there are no local regulations and no instruction from your insurance company, it is necessary to have your fume pipe, chim-
ney flue and chimney pot cleaned at least once a year.
• It is also necessary to have the combustion chamber, motors and fans cleaned and to have the gaskets and the electronical
elements checked at least once a year.
All these operations must be planned in time with your Autorized Technical Assistance Service.
• After a long ineffective time, before turning on the stove check if there are obstructions in the fume exhaust.
• If the stove had been using continuously and intensely, the whole system (chimney included), must be cleaned and checked
more frequently.
• In case of replacement of damaged pieces please ask for the original spare part at the Autorized Retailer.
7.2
FUME CHAMBER CLEANING
Every end-of-season (or every 2000 hours of operation) it is necessary to clean the fume chamber.
• Open the door and release the panel below the door (see dedicated chapter).
• Remove the burning pot (see
Fig. 78
) from its seat and empty all ash.
• Clean and vacuum the burning pot compartment of any ash accumulated inside (see
Fig. 79
).
• Remove the inspection cap (see
Fig. 80
).