27
KOBE - FENICE - SPARK - INDACO - PRINCE - GO - ECLIPSE
Fig. 74 - Electric socket with master switch
Fig. 75 - Plug connected
• Do not use extension cables.
• If the feeder cable is damaged, it must be replaced by an authorized technician.
• When the stove is not going to be used for a long period of time, it advisable to remove the plug from the socket on the wall.
• An electrical connection to a UPS/ACCUMULATOR/ STABILISER must guarantee a voltage of at least 210 V without power
surges. Considering the variety of UPS on the market regarding size and construction qualities, we cannot guarantee operation
once the stove is connected to these devices.
6.21 CONNECTION TO THE EXTERNAL THERMOSTAT
Fig. 76 - Graphic display
The stove works through a thermostat probe placed in its inner. If you desire, the stove can be connected to an external room
thermostat. This operation must be executed by an authorized technician.
Connect the wires from the external thermostat to the "Term opt" terminal on the stove board. Activate the external thermostat
(default setting OFF) as indicated below:
• Press the "
menu
" button.
• Scroll with the arrows to "
Settings
".
• Select by pressing "
menu
".
• Scroll with the arrows again to "
Ext.Thermostat
".
• Select by pressing "
menu
".
• Press the
- +
buttons.
• To activate the external thermostat select "
on
".
• Press the "
menu
" button to confirm.
6.22 STOVE CALIBRATION AND DEPRESSION MEASUREMENT
This stove has a pickup point positioned on the tank in order to measure the depression of the combustion chamber and verify its
proper operation.
To do this, proceed as follows:
• Connect a digital pressure switch with a tube to detect the negative pressure (see
Fig. 77
).
• Load the feed screw via appropriate function.
• Start the stove and set "Set flame" to power 1 (the start-up time of this stove lasts between 8 and 10 minutes to ensure mini-
mum draught).
• Compare the read values with those on the table.
• Change power every 10 minutes and wait for it to stabilise.
• Access the user menu and, if necessary, change the parameters.