CRISTAL 9 - LIFE 9 - CRISTAL PLUS 9 - ICON PLUS 9 - STEEL 9
20
The ECO switch off procedure is automatically activated when the power recall device is activated (Room probe +1°C or external
thermostat with open contact, see
Fig. 18
). "
t Off Time Eco
" time decrease starts (5 minutes by default, see
Fig. 19
, and can be
modified from the "Settings" menu). During this phase the panel view is activated ON with the small flame and alternates chrono
(if ON) - active Eco.
Fig. 18 - Active eco 1
Fig. 19 - Active eco 2
Fig. 20 - Active eco 3
On the upper display the minutes for the Eco Stop countdown are shown. The flame goes to P1, where it remains until the set "
t
Off Time Eco
" time is over and, if conditions are still met, it switches to the switch-off process. The ECO switch-off countdown is
reset if one of the devices resumes recalling power.
When the switch-off procedure begins, the panel shows: Off - Active Eco - small flashing flame (see
Fig. 20
).
When the stove is switched off, the panel shows active OFF-ECO with the flame icon off.
For an ECO switch on, the following conditions must be met simultaneously:
• Room probe -1°C or external thermostat with closed contact (for at least 20" to avoid false recalls).
• After 5 minutes from the beginning of the switch-off procedure.
8.15 SLEEP FUNCTION (MAIN MENU)
The sleep function is activated only when the boiler is switched on and allows to quickly set a time at which the product must
switch off.
To set the Sleep function act as follows:
• Enter MENU
• Scroll to SLEEP with the <> arrows
• Press Menu
• With the + - keys adjust the desired shutdown time.
The panel proposes a shutdown time of 10 minutes from the current time, adjustable with key 4 until the next day (I can therefore
delay the shutdown for up to a maximum of 23 hours and 50 minutes).
Fig. 21 - Sleep
If the SLEEP function is active with the TIMER active the first has priority over the latter, therefore the boiler will not switch off at
the time set on the timer but instead by the time established by the sleep function, even if later than the time set on the timer.
8.16 EASY SET FEATURE (SEE SECTION X SETTINGS MENU A PAG. 14)
Proper operation of a stove mainly depends on the flue it is connected to. Once it is connected, it is equally important to perform
proper adjustment of combustion parameters.
The Easy Set feature makes it possible to adjust combustion more easily, in the event that one should notice that the stove does
not properly burn the fuel.
In the “Settings” menu, under the heading Easy Set, there are 4 configurations, SET1-SET2-SET3-SET4.
Select the SET based on the type of installation and, should the result not be satisfactory, try the other available settings.
Caution, before changing the stove’s programming :
• It is recommended to change the factory settings under the supervision of an authorised technician.
• Before installation, ensure the flue has been installed and certified by suitable personnel according to the legal provisions in
force.
Содержание CRISTAL 9